Commercial & Industrial Power Equipment Worldwide

Equipment for use in
10 kW Triton Diesel Generator TP-P10-T4i EPA Certified
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 4 technical documentsspec sheet, engine data, alternator data, brochure
60 Hz USA EPA Tier 4

10 kW Triton Diesel Generator TP-P10-T4i EPA Certified

SKU TP-10-T4i Model TP-P10-T14i

Standby rating

10 kW 12.4 kVA

Prime rating

9 kW 11.2 kVA

Engine
Perkins 403D-11G
Alternator
Leroy Somer LSA40VS1
Control panel
DSE7420
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480 · 120/240
Configuration
Enclosed · Open
Fuel tank
Not specified

Market compatibility

USA EPA-certified

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.

Specifications being verified

Our engineering team is confirming some details on this page (model). Please confirm model and ratings with sales before ordering.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-10-T4i is a 12.4 kVA / 10 kW standby, 11.2 kVA / 9 kW prime diesel generator, EPA-certified for the US market.

It uses a Perkins 403D-11G engine, a Leroy Somer LSA40VS1 alternator and a DSE7420 control panel.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.

  • Powered by Perkins 403D-11G
  • Emissions: Tier 4 interim EPA Certified Emergency Stationary Applications
  • 60 Hz Power Rating at 3 Phase
  • Standby Power Rating: 12.4 kVA / 10 kW
  • Prime Power Rating: 11.2 kVA / 9 kW
Read the full product description

Global Generator Supply provides Emergency Stationary generators that are certified to Tier 4i, 3 and 2 depending upon the generator rating required. We provide UL2200, CSA and other certifications. Triton can build nearly any type of generator for your requirements, including both gaseous and diesel generators. Further, we maintain a stock of generators built to standard specifications for immediate shipment, including trailers, transfer switches and fuel tanks.

Triton EPA Generators are to exacting standards for the US and Canadian markets. We provide options for everything from hurricane zones to the harsh environment of the far north. Triton Generators are used at a variety of locations including government facilities, hotels, factories, medical facilities and grocery stores.

Our TP-10-T4i provides a standby rating of 10kW / 12.4kVA and a prime rating of 9kW / 11.2kVA. The TP-10-T4i is built to rugged specifications and provides the power where and when you need it. By utilizing a Perkins engine model 403D-11G, this generator set will provide you with the EPA standards and also provide unsurpassed performance and reliability.

The TP-10-T4i includes just a few of the following features:

Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open and Enclosed
8 to 10 Hours Fuel Tank

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.

Why choose this model

  • Perkins 403D-11G engineEngine data sheet included below
  • Standby & prime rated10 kW / 12.4 kVA standby · 9 kW / 11.2 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480, 120/240
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA40VS1 alternatorAlternator specifications included below
  • DSE7420 control panelControl panel listed for this model

Typical applications

Listed in our industry catalogs: Restaurants & hospitality

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-P10-T14i
kVA / kW Standby 12.4 kVA / 10 kW
kVA / kW Prime 11.2 kVA / 9 kW
Engine
Engine Brand Perkins
Engine Model 403D-11G
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA40VS1
Electrical
Voltages Available 120/208, 277/480, 120/240
Fuel System
Fuel Tank Capacity N/A
Control
Control Panel DSE7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 4 interim EPA Certified Emergency Stationary Applications
MarketUSA EPA-certified
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-10-T4i with similar models
ModelTP-10-T4iThis model TP-14-T4iTP-20-T4iTP-P20-T4i-ULTP-29-T4i
Standby10 kW / 12.4 kVA15 kW / 20 kVA20 kW / 26 kVA20 kW / 26 kVA29 kW / 37 kVA
Prime9 kW / 11.2 kVA14 kW / 18 kVA18 kW / 24 kVA18 kW / 24 kVA27 kW / 35 kVA
EnginePerkins 403D-11GPerkins 403D-15GPerkins 404D-22GPerkins 404D-22GPerkins 404D-22TG
AlternatorLeroy Somer LSA40VS1Leroy Somer LSA40S4Leroy Somer LSA 40 M5Leroy Somer LSA40M5Leroy Somer LSA 42.3 VS2
Control panelDSE7420DSE7420DSE7420Deep Sea DSE 7420DSE7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240
ConfigurationEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, Open SkidEnclosed, Open
Fuel tank—————
MarketUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certified
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

Supported by Global Generator Supply

+1 251-314-4812

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request