60 HzInternational
500 kW Triton Diesel Generator TP-P500-T1 International Use
TP-P500-T1
Engine Perkins 2506A-E15TAG4
- Standby
- 501 kW / 626 kVA
- Prime
- 455 kW / 569 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
This band of 501-1000 kW commercial generators holds 40 diesel sets rated between 501 kW and 1,011 kW standby. Perkins engines appear most often (18 units), followed by Doosan (8), Cummins (6), Volvo (4) and Scania (4).
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.
60 HzInternational
TP-P500-T1
Engine Perkins 2506A-E15TAG4
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P600-T1-50
Engine Perkins 2806C-E18TAG1A
Diesel · 50 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V550-T4F
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV625-T4F-RENTAL
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P550-T2
Engine Perkins 2506C-E15TAG4
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-D550-T1
Engine Doosan DP180LA
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P650-T1-50
Engine Perkins 2806A-E18TAG2
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-P600-T1
Engine Perkins 2806A-E18TAG3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P600-T2
Engine Perkins 2806C-E18TAG3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P600-T2-UL
Engine Perkins 2806C-E18TAG3
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-D600-T1
Engine Doosan DP180LB
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS700-T4F-Twin Pack
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
Not sure which generator you need?
Tell us what you're powering, the destination country, the estimated load and whether it is standby or prime, and our team can help recommend a suitable generator.
60 HzTier 4 FinalMobile
TP-V625-T4F
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV713-T4F-RENTAL
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-P660-T1
Engine Perkins 4006-23TAG2A
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P660-T1-50
Engine Perkins 4006-23TAG2A
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-P770-T1-50
Engine Perkins 2806A-E18TTAG5
Diesel · 50 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S700-T4F-Twin Pack
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P750-T1-50
Engine Perkins 4006-23TAG3A
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-D700-T1
Engine Doosan DP222LB
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-C800-T1-S-50
Engine Cummins QSK23-G3
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-P750-T1
Engine Perkins 4006-23TAG3A
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P750-T2-UL
Engine Perkins 2806C-E18TTAG7
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-D750-T1
Engine Doosan DP222LC
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P900-T1-50
Engine Perkins 4008TAG1A
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-C800-T2-60
Engine Cummins QSK23-G7
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C800-T1-S
Engine Cummins QSK23-G3
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-D800-T1
Engine Doosan DP222CB
Diesel · 60 Hz · Enclosed or open
60 HzConfirming
TP-D800-T2-UL
Engine Doosan DP222CB
Diesel · 60 Hz · Enclosed or open
Market eligibility being confirmed
60 HzInternational
TP-P875-T1
Engine Perkins 4008TAG2
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P875-T1-50
Engine Perkins 4008TAG2
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-CK1000-T1-C-50
Engine Cummins KTA38-G5
Diesel · 50 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S880-T4F-Twin Pack
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS1000-T4F-Twin Pack
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzConfirming
TP-D900-T2-UL
Engine Doosan DP222CC
Diesel · 60 Hz · Enclosed or open
Market eligibility being confirmed
60 HzConfirmingMobile
TP-D900-T2-60
Engine Doosan DP222CC
Diesel · 60 Hz · Enclosed or open
Market eligibility being confirmed
50 HzInternational
TP-P1125-T1-50
Engine Perkins 4008-30TAG3
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-C1000-T2-60
Engine Cummins QST30-G5
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P1000-T2-S-UL
Engine Perkins 5008C-E30TAG5
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-CK1000-T1-C
Engine Cummins KTA38-G4
Diesel · 60 Hz · Enclosed or open
Showing 24 of 40
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 40 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 40 units here, 10 at 50 Hz and 30 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 40 of the 40 units here are offered in more than one configuration. 9 are mobile units.
Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
This band of 501-1000 kW commercial generators holds 40 diesel sets rated between 501 kW and 1,011 kW standby. Perkins engines appear most often (18 units), followed by Doosan (8), Cummins (6), Volvo (4) and Scania (4). Output frequency is 60 Hz on 30 units and 50 Hz on 10.
All 40 list both enclosed and open configurations, and 9 are mobile units. To compare only the US-market or only the international sets, go to EPA generators or export generators in the same power band.
Tell us your required power, destination and application. Our team can help identify the right generator.