John Deere Industrial Generators

All 15 John Deere industrial generators in this group are mobile Triton diesel sets, and all 15 carry the Tier 4 Final label. Standby ratings run from 50 to 440 kW.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power

15 of 15 generators

Generators

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 15 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 15 units here, 15 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 15 of the 15 units here are offered in more than one configuration. 15 are mobile units.

USA EPA, Tier 4 Final or international?
  • Tier 4 Final (15 here): Tier 4 Final emissions configuration.

About John Deere Industrial Generators

All 15 John Deere industrial generators in this group are mobile Triton diesel sets, and all 15 carry the Tier 4 Final label. Standby ratings run from 50 to 440 kW. Every unit is a 60 Hz machine, which matches most North American sites; where the grid or the equipment runs on 50 Hz, as in Europe and much of Asia and Africa, these units are not the right match.

kW, kVA and the right rating

The kW values on these listings are standby ratings, for backup power during an outage. When a set will be a site's main power source for long periods, with a load that varies, choose on its prime rating; that figure sits below the same set's standby rating. Spec sheets sometimes give kVA rather than kW. To move between the two, divide kW by the power factor; generator ratings normally assume 0.8, and the kW to kVA calculator does the sum.

Each listing shows both enclosed and open configurations. For other Tier 4 Final sets, see Tier 4 generators. Send your requirements through the quote form, including the load and how the set will be used.