Commercial & Industrial Power Equipment Worldwide

Equipment for use in

Diesel Generators

This page gathers 181 diesel generators, starting at 8 kW and running up to 3,300 kW standby, from compact sets to large industrial units. The engine is often the first filter buyers apply, and the makes break down as follows.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Frequency
Market
Engine
Configuration
Type

Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.

181 of 181 generators

Generators

Showing 24 of 181

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 181 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 181 units here, 40 at 50 Hz and 141 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 180 of the 181 units here are offered in more than one configuration. 44 are mobile units.

USA EPA, Tier 4 Final or international?
  • USA EPA (52 here): EPA-certified configuration for the US market.
  • Tier 4 Final (39 here): Tier 4 Final emissions configuration.
  • International (84 here): Configured for international markets (non-EPA).

Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.

About Diesel Generators

This page gathers 181 diesel generators, starting at 8 kW and running up to 3,300 kW standby, from compact sets to large industrial units. The engine is often the first filter buyers apply, and the makes break down as follows.

Engine makes

  • Perkins: 94 units.
  • Cummins: 22; John Deere: 15; Doosan: 14.
  • Scania: 10; Volvo: 8; Baudouin: 7.
  • Kubota: 6; Yanmar: 5.

Output is 60 Hz on 141 units and 50 Hz on 40, so match the frequency to the grid at the site. Market labels vary: 52 are USA EPA-certified, 39 carry Tier 4 Final, 84 are International, and 6 have eligibility still being confirmed. Enclosed configurations appear on all 181 units, open sets on 167 and open skids on 13, while 44 units are mobile. If you are weighing a gas-fueled set instead, see natural gas and LP generators.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.