60 HzUSA EPA
200 kW Triton Diesel Generator TP-C200-T3 EPA Certified
TP-C200-T3
Engine Cummins QSB7-G5
- Standby
- 200 kW / 250 kVA
- Prime
- 180 kW / 225 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
All 22 units here are Cummins commercial generators, diesel sets rated from 200 kW to 2,500 kW standby. The first thing to check on any listing is its market label, because the group divides cleanly by market.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.
60 HzUSA EPA
TP-C200-T3
Engine Cummins QSB7-G5
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C250-T3
Engine Cummins QSL9-G3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C300-T3-SAE
Engine Cummins QSL9-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C350-T3-SAE
Engine Cummins QSZ13-G6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C400-T3-SAE
Engine Cummins QSZ13-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C450-T3
Engine Cummins QSX15-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C500-T3
Engine Cummins QSX15-G9
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-C800-T1-S-50
Engine Cummins QSK23-G3
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-C800-T2-60
Engine Cummins QSK23-G7
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C800-T1-S
Engine Cummins QSK23-G3
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-CK1000-T1-C-50
Engine Cummins KTA38-G5
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-C1000-T2-60
Engine Cummins QST30-G5
Diesel · 60 Hz · Enclosed or open
Not sure which generator you need?
Tell us what you're powering, the destination country, the estimated load and whether it is standby or prime, and our team can help recommend a suitable generator.
60 HzInternational
TP-CK1000-T1-C
Engine Cummins KTA38-G4
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-C1250-T1-C-50
Engine Cummins KTA50-G3
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-CK1250-T1-C-60
Engine Cummins KTA50-G3
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C1500-T1-C
Engine Cummins KTA50-G9
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C1500-T2-60
Engine Cummins QSK50-G4
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-C2000-T1-C-50
Engine Cummins QSK60-G7
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-C2000-T2-60
Engine Cummins QSK60-G6
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C2000-T1-C-60
Engine Cummins QSK60-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C2250-T2-60
Engine Cummins QSK60-G14
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C2500-T1-C-60
Engine Cummins QSK78-G7
Diesel · 60 Hz · Enclosed or open
Showing 22 of 22
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 22 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 22 units here, 4 at 50 Hz and 18 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 22 of the 22 units here are offered in more than one configuration. 4 are mobile units.
Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
All 22 units here are Cummins commercial generators, diesel sets rated from 200 kW to 2,500 kW standby. The first thing to check on any listing is its market label, because the group divides cleanly by market.
USA EPA-certified applies to 12 units, which means an "EPA-certified configuration for the US market." The other 10 are International. Units marked International are built for markets outside the United States and Canada. Their description reads "Configured for international markets (non-EPA)." On frequency, 18 units produce 60 Hz and 4 produce 50 Hz, and 4 units are mobile.
Each unit lists enclosed and open configurations, so the remaining decision is usually between an open set for an indoor room and an enclosure for weather and sound protection outside. To compare within a single market, see Cummins EPA generators or Cummins export generators.
Tell us your required power, destination and application. Our team can help identify the right generator.