Commercial & Industrial Power Equipment Worldwide

Equipment for use in

Mobile Generators

Mobile generators on this page range from 13.5 kW to 1254 kW standby. All 44 are diesel units running at 60 Hz, and each one lists enclosed and open configurations as options.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Market
Engine

44 of 44 generators

Generators

Showing 24 of 44

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 44 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 44 units here, 44 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 44 of the 44 units here are offered in more than one configuration. 44 are mobile units.

USA EPA, Tier 4 Final or international?
  • USA EPA (4 here): EPA-certified configuration for the US market.
  • Tier 4 Final (39 here): Tier 4 Final emissions configuration.

About Mobile Generators

Mobile generators on this page range from 13.5 kW to 1254 kW standby. All 44 are diesel units running at 60 Hz, and each one lists enclosed and open configurations as options.

By emissions label, 39 are Tier 4 Final, 4 are USA EPA-certified, and 1 has its eligibility still being confirmed. Engines come from John Deere (15), Scania (10), Volvo (8), Kubota (6), Cummins (4) and Doosan (1).

Choosing a mobile set for the job

On a job site with no grid connection, the generator is the main power source, often for long stretches with a load that changes through the day. In that case the prime rating is the number to plan around; for any given set it is the lower of the two ratings. The standby rating applies when the set stands in for the utility during an outage.

Two engine groups have pages of their own: the Kubota diesel generators, which start at 13.5 kW, and the John Deere industrial generators, which account for 15 of the mobile units. Our team can help confirm the right unit if you send your requirements through the quote form.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.