Commercial & Industrial Power Equipment Worldwide

Equipment for use in

60 Hz Generators

Every generator on this page is published with a 60 Hz rating, including USA EPA-certified, Tier 4 Final and international (non-EPA) units. Filter by market to see only the units eligible for your destination.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Market
Engine
Configuration
Type
Duty
Fuel

Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.

145 of 145 generators

Generators

Showing 24 of 145

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

142 of the 145 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 145 units here, 145 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 140 of the 145 units here are offered in more than one configuration. 44 are mobile units.

USA EPA, Tier 4 Final or international?
  • USA EPA (56 here): EPA-certified configuration for the US market.
  • Tier 4 Final (39 here): Tier 4 Final emissions configuration.
  • International (44 here): Configured for international markets (non-EPA).

Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.

About 60 Hz Generators

Generator frequency has to match the grid and the equipment it will power. Units marked International are not EPA-certified. Their product pages carry the published US/Canada restriction. If you are unsure which frequency or voltage your site uses, tell us the destination and our engineers will confirm the configuration.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.