60 HzUSA EPA
40 kW Triton Natural Gas Generator TP-NG40-S-K-UL EPA – UL Listed
TP-NG40-S-K-UL
Engine PSI Engine 4.3L
- Standby
- 40 kW / 50 kVA
- Prime
- 34 kW / 44 kVA
Natural gas / LP · 60 Hz
Commercial & Industrial Power Equipment Worldwide
Natural Gas & LP Generators burn a gaseous fuel instead of diesel. This category lists 4 Triton generators, each fitted with a PSI / GM engine, with standby ratings between 40 kW and 250 kW.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzUSA EPA
TP-NG40-S-K-UL
Engine PSI Engine 4.3L
Natural gas / LP · 60 Hz
60 HzUSA EPA
TP-NG80-S-K-UL
Engine PSI Engine 5.7LT
Natural gas / LP · 60 Hz
60 HzUSA EPA
TP-NG100-S-K-UL
Engine PSI Engine 5.7LT CAC
Natural gas / LP · 60 Hz
60 HzUSA EPA
TP-NG250-S-K-UL
Engine PSI Engine PSI 13 L
Natural gas / LP · 60 Hz
Showing 4 of 4
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
1 of the 4 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 4 units here, 4 at 60 Hz.
Each unit's page lists the configurations it is offered in, with dimensions and weights where published.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
Natural Gas & LP Generators burn a gaseous fuel instead of diesel. This category lists 4 Triton generators, each fitted with a PSI / GM engine, with standby ratings between 40 kW and 250 kW.
Those kW figures describe standby duty: the output a set is sized to supply as backup when utility power is lost. A generator that will be the main source of power for long stretches under a varying load is judged on its prime rating instead, and that rating sits below the standby number for the same unit.
Because ratings are normally stated at a 0.8 power factor, dividing kW by 0.8 gives kVA; the kW to kVA converter handles the math. Once the shortlist is clear, send your requirements through the quote form.
Tell us your required power, destination and application. Our team can help identify the right generator.