60 HzTier 4 FinalMobile
200 kW Triton Diesel Generator TP-JD200-T4F Tier 4 Final
TP-JD200-T4F
Engine John Deere 6068CG550
- Standby
- 200 kW / 250 kVA
- Prime
- 180 kW / 225 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
Manufacturing generators in this group are 121 Triton sets with standby ratings from 200 to 3300 kW. Diesel fuels 120 of them; one runs on natural gas or LP.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.
60 HzTier 4 FinalMobile
TP-JD200-T4F
Engine John Deere 6068CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD225-T4F-RENTAL
Engine John Deere 6068CG550
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-P200-T1
Engine Perkins 1206A-E70TTAG2
Diesel · 60 Hz · Enclosed or open
60 HzConfirming
TP-P200-T3
Engine Perkins 1106D-E70TAG5
Diesel · 60 Hz · Enclosed or open
Market eligibility being confirmed
60 HzUSA EPA
TP-P200-T3-UL
Engine Perkins 1106D-E70TAG5
Diesel · 60 Hz · Enclosed or open skid
60 HzInternational
TP-D200-T1
Engine Doosan P086TI
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C200-T3
Engine Cummins QSB7-G5
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P220-T1-50
Engine Perkins 1206A-E70TTAG3
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-P250-T3-UL
Engine Perkins 1706D-E93TAG1
Diesel · 60 Hz · Enclosed or open skid
60 HzUSA EPA
TP-NG250-S-K-UL
Engine PSI Engine PSI 13 L
Natural gas / LP · 60 Hz
60 HzUSA EPA
TP-C250-T3
Engine Cummins QSL9-G3
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P310-T1-50
Engine Perkins 1506A-E88TAG5
Diesel · 50 Hz · Enclosed or open
Not sure which generator you need?
Tell us what you're powering, the destination country, the estimated load and whether it is standby or prime, and our team can help recommend a suitable generator.
50 HzInternational
TP-P300-T1-50
Engine Perkins 1706A-E93TAG1
Diesel · 50 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD288-T4F
Engine John Deere 6090CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S300-T4F
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD325-T4F-RENTAL
Engine John Deere 6090CG550
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C300-T3-SAE
Engine Cummins QSL9-G7
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS350-T4F-RENTAL
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P350-T1-50
Engine Perkins 2206C-E13TAG2
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-P300-T3-UL
Engine Perkins 1706D-E93TAG2
Diesel · 60 Hz · Enclosed or open skid
60 HzInternational
TP-D300-T1
Engine Doosan P126TI-II
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-P310-T1-50
Engine Perkins 1706A-E93TAG1
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-P310-T1-S-K-60
Engine Perkins 1706A-E93TAG1
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P400-T1-50
Engine Perkins 2206A-E13TAG6
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-D350-T1
Engine Doosan DP126LB
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S350-T4F
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-P350-T1
Engine Perkins 2206A-E13TAG5
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P350-T3
Engine Perkins 2206D-E13TAG2
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P350-T3-UL
Engine Perkins 2206D-E13TAG2
Diesel · 60 Hz · Enclosed or open skid
60 HzTier 4 FinalMobile
TP-RS400-T4F-RENTAL
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C350-T3-SAE
Engine Cummins QSZ13-G6
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P450-T1-50
Engine Perkins 2506C-E15TAG1
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-P400-T3
Engine Perkins 2206D-E13TAG3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P400-T3-UL
Engine Perkins 2206D-E13TAG3
Diesel · 60 Hz · Enclosed or open skid
60 HzInternational
TP-P400-T1
Engine Perkins 2206A-E13TAG6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C400-T3-SAE
Engine Cummins QSZ13-G7
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-D400-T1
Engine Doosan P158LE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S440-T4F
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS500-T4F-RENTAL
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P500-T1-50
Engine Perkins 2506C-E15TAG2
Diesel · 50 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD440-T4F
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD500-T4F
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD500-T4F-RENTAL
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P450-T3
Engine Perkins 2506D-E15TAG1
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C450-T3
Engine Cummins QSX15-G7
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-D450-T1
Engine Doosan DP158LC
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P500-T2
Engine Perkins 2506C-E15TAG3L
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P500-T2-UL
Engine Perkins 2506C-E15TAG3L
Diesel · 60 Hz · Enclosed or open skid
60 HzInternational
TP-D500-T1
Engine Doosan DP158LD
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C500-T3
Engine Cummins QSX15-G9
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-P500-T1
Engine Perkins 2506A-E15TAG4
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P600-T1-50
Engine Perkins 2806C-E18TAG1A
Diesel · 50 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V550-T4F
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV625-T4F-RENTAL
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P550-T2
Engine Perkins 2506C-E15TAG4
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-D550-T1
Engine Doosan DP180LA
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P650-T1-50
Engine Perkins 2806A-E18TAG2
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-P600-T1
Engine Perkins 2806A-E18TAG3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P600-T2
Engine Perkins 2806C-E18TAG3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P600-T2-UL
Engine Perkins 2806C-E18TAG3
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-D600-T1
Engine Doosan DP180LB
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS700-T4F-Twin Pack
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V625-T4F
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV713-T4F-RENTAL
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-P660-T1
Engine Perkins 4006-23TAG2A
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P660-T1-50
Engine Perkins 4006-23TAG2A
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-P770-T1-50
Engine Perkins 2806A-E18TTAG5
Diesel · 50 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S700-T4F-Twin Pack
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P750-T1-50
Engine Perkins 4006-23TAG3A
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-D700-T1
Engine Doosan DP222LB
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-C800-T1-S-50
Engine Cummins QSK23-G3
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-P750-T1
Engine Perkins 4006-23TAG3A
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P750-T2-UL
Engine Perkins 2806C-E18TTAG7
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-D750-T1
Engine Doosan DP222LC
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P900-T1-50
Engine Perkins 4008TAG1A
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-C800-T2-60
Engine Cummins QSK23-G7
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C800-T1-S
Engine Cummins QSK23-G3
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-D800-T1
Engine Doosan DP222CB
Diesel · 60 Hz · Enclosed or open
60 HzConfirming
TP-D800-T2-UL
Engine Doosan DP222CB
Diesel · 60 Hz · Enclosed or open
Market eligibility being confirmed
60 HzInternational
TP-P875-T1
Engine Perkins 4008TAG2
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P875-T1-50
Engine Perkins 4008TAG2
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-CK1000-T1-C-50
Engine Cummins KTA38-G5
Diesel · 50 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S880-T4F-Twin Pack
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS1000-T4F-Twin Pack
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzConfirming
TP-D900-T2-UL
Engine Doosan DP222CC
Diesel · 60 Hz · Enclosed or open
Market eligibility being confirmed
60 HzConfirmingMobile
TP-D900-T2-60
Engine Doosan DP222CC
Diesel · 60 Hz · Enclosed or open
Market eligibility being confirmed
50 HzInternational
TP-P1125-T1-50
Engine Perkins 4008-30TAG3
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-C1000-T2-60
Engine Cummins QST30-G5
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P1000-T2-S-UL
Engine Perkins 5008C-E30TAG5
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-CK1000-T1-C
Engine Cummins KTA38-G4
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V1100-T4F-Twin Pack
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV1250-T4F-RENTAL TWIN PACK
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P1100-T1-50
Engine Perkins 4012-46TWG2A
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-P1100-T1
Engine Perkins 4012-46TWG2A
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-C1250-T1-C-50
Engine Cummins KTA50-G3
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-P1200-T1-60
Engine Perkins 4012-46TWG3A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV1425-T4F-RENTAL TWIN PACK
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V1250-T4F-Twin Pack
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-CK1250-T1-C-60
Engine Cummins KTA50-G3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B1300-T2-60-UL
Engine Baudoin 12M33G12D2/6
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P1330-T1-50
Engine Perkins 4012-46TAG2A
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-P1330-T1
Engine Perkins 4012-46TAG2A
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C1500-T1-C
Engine Cummins KTA50-G9
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C1500-T2-60
Engine Cummins QSK50-G4
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B1500-T2-60-UL
Engine Baudoin 16M33G12D2/6
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P1500-T1-60
Engine Perkins 4012-46TAG3A
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-P1500-T1-50
Engine Perkins 4012-46TAG3A
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-P1750-T1-50
Engine Perkins 4016TAG1A
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-P1850-T1-50
Engine Perkins 4016-61TRG1
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-B1750-T2-60-UL
Engine Baudouin 16M33G4D2/6
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P2000-T1-50
Engine Perkins 4016-61TRG2
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-C2000-T1-C-50
Engine Cummins QSK60-G7
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-P2250-T1-50
Engine Perkins 4016-61TRG3
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-C2000-T2-60
Engine Cummins QSK60-G6
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C2000-T1-C-60
Engine Cummins QSK60-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B2000-T2-60-UL
Engine Baudoin 20M33G4D2/6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C2250-T2-60
Engine Cummins QSK60-G14
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C2500-T1-C-60
Engine Cummins QSK78-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B2500-T2-60-UL
Engine Baudoin 12M55G5D2/6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B3000-T2-60-UL
Engine Baudoin 16M55G6D2/6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-B3300-T2-60-UL
Engine Baudoin 16M55G8D2/6
Diesel · 60 Hz · Enclosed or open
Showing 24 of 121
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
120 of the 121 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 121 units here, 27 at 50 Hz and 94 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 120 of the 121 units here are offered in more than one configuration. 30 are mobile units.
Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
Manufacturing generators in this group are 121 Triton sets with standby ratings from 200 to 3300 kW. Diesel fuels 120 of them; one runs on natural gas or LP.
A plant that keeps a generator for outages buys on the standby rating. A plant that runs a set as its main power source, for long shifts and under a load that changes with production, should plan on the prime rating, which comes in below the standby rating for the same set. The prime and backup generators page sets the two side by side.
Frequency matters on a factory floor because motors and machinery are built for one or the other. Here, 94 sets are built for 60 Hz, which North America mainly uses, and 27 for 50 Hz, common in Europe and much of Asia and Africa. By market label, 57 are International, 35 USA EPA-certified, 25 Tier 4 Final and 4 still being confirmed.
Engines include Perkins (52), Cummins (22), Doosan (14), Scania (10), Volvo (8), John Deere (7), Baudouin (7) and PSI / GM (1). For a new plant or an expansion, tell us the destination country and the load.
Tell us your required power, destination and application. Our team can help identify the right generator.