Commercial & Industrial Power Equipment Worldwide

Equipment for use in

Military Generators

Military generators in this group are aimed at defense and government users, and nearly all of them are designed to move: 38 of the 39 are mobile units.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

39 generators suited to military & government projects · All inventory, new and used

Power
Frequency
Market
Engine
Type

Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.

39 of 39 generators

Generators

Showing 24 of 39

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 39 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 39 units here, 1 at 50 Hz and 38 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 39 of the 39 units here are offered in more than one configuration. 38 are mobile units.

USA EPA, Tier 4 Final or international?
  • Tier 4 Final (38 here): Tier 4 Final emissions configuration.
  • International (1 here): Configured for international markets (non-EPA).

Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.

About Military Generators

Military generators in this group are aimed at defense and government users, and nearly all of them are designed to move: 38 of the 39 are mobile units. Standby ratings run from 13.5 kW up to 1254 kW, so the list spans small field sets as well as much larger ones. All 39 are diesel.

Market and frequency

By market label, 38 are Tier 4 Final and 1 is International. Units marked International are built for markets outside the United States and Canada. By frequency, 38 run at 60 Hz and 1 at 50 Hz. That matters for deployments abroad, since the set has to suit the grid and the equipment it powers: North America mainly uses 60 Hz, while 50 Hz is the norm across Europe and in much of Asia and Africa.

Engines come from John Deere (14), Scania (10), Volvo (8), Kubota (6) and Cummins (1). On every listing the set can be specified open, for use inside a shelter or building, or enclosed, to protect it from weather and keep noise down outdoors. See mobile generators for the wider group of mobile units, and tell us the destination country and the load.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.