Equipment for use in

101-300 kW Diesel Generators

Engine make is the quickest way to sort this list. The 101-300 kW Diesel Generators here are 33 Triton units, rated from 110 kW to 316 kW standby, with engines from the makers below.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Frequency
Market
Engine
Configuration
Type

Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.

33 of 33 generators

Generators

Showing 24 of 33

Buyer's guide

Choosing a 101–300 kW generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 33 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 33 units here, 7 at 50 Hz and 26 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 33 of the 33 units here are offered in more than one configuration. 9 are mobile units.

USA EPA, Tier 4 Final or international?
  • USA EPA (9 here): EPA-certified configuration for the US market.
  • Tier 4 Final (9 here): Tier 4 Final emissions configuration.
  • International (13 here): Configured for international markets (non-EPA).

Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.

About 101-300 kW Diesel Generators

Engine make is the quickest way to sort this list. The 101-300 kW Diesel Generators here are 33 Triton units, rated from 110 kW to 316 kW standby, with engines from the makers below.

Engines in this group

  • Perkins: 19 units.
  • John Deere: 8 units.
  • Cummins: 3 units.
  • Doosan: 2 units.
  • Scania: 1 unit.

Market labels differ across the list. Units marked International are built for markets outside the United States and Canada; 13 units here carry that label. Another 9 are USA EPA-certified, 9 are Tier 4 Final, and for 2 the market eligibility is still being confirmed. On frequency, 26 run at 60 Hz and 7 at 50 Hz.

Enclosed versions are listed for all 33, open sets for 29 and open skids for 4, and 9 units are mobile. Compare the export and EPA subsets for a narrower view. Our team can help confirm the right unit.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.