Commercial & Industrial Power Equipment Worldwide

Equipment for use in

Data Center Generators

Data center generators are usually specified on their standby rating, the figure for backup power during a utility outage.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

62 generators suited to data centers projects · All inventory, new and used

Power
Frequency
Market
Engine
Configuration
Type

Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.

62 of 62 generators

Generators

Showing 24 of 62

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 62 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 62 units here, 1 at 50 Hz and 61 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 62 of the 62 units here are offered in more than one configuration. 33 are mobile units.

USA EPA, Tier 4 Final or international?
  • USA EPA (30 here): EPA-certified configuration for the US market.
  • Tier 4 Final (30 here): Tier 4 Final emissions configuration.
  • International (1 here): Configured for international markets (non-EPA).

Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.

About Data Center Generators

Data center generators are usually specified on their standby rating, the figure for backup power during a utility outage. The 62 diesel units grouped for data centers here range from 88 kW to 2,250 kW standby; 61 of them produce 60 Hz power and 1 produces 50 Hz.

Market labels on these units

  • Tier 4 Final: 30 units.
  • USA EPA-certified: 30 units.
  • International: 1 unit.
  • Eligibility being confirmed: 1 unit.

For layout, an enclosed configuration appears on all 62 listings, an open set on 55 and an open skid on 7. Open sets belong in an indoor generator room; an enclosure is the choice for rooftop or yard placement, where it adds weather and sound protection. Engines include Perkins (20), John Deere (12), Cummins (12), Scania (10) and Volvo (8), and 33 units are mobile. For the load you need to back up, our team can help confirm the right unit.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.