Commercial & Industrial Power Equipment Worldwide

Equipment for use in

Export Generators

Every one of the 84 Triton diesel sets in this category carries the International market label. Configured for international markets (non-EPA). Units marked International are built for markets outside the United States and Canada.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Frequency
Engine

Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.

84 of 84 generators

Generators

Showing 24 of 84

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 84 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 84 units here, 40 at 50 Hz and 44 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 84 of the 84 units here are offered in more than one configuration.

USA EPA, Tier 4 Final or international?
  • International (84 here): Configured for international markets (non-EPA).

Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.

About Export Generators

Every one of the 84 Triton diesel sets in this category carries the International market label. Configured for international markets (non-EPA). Units marked International are built for markets outside the United States and Canada.

Choosing the frequency

The export generators are split almost evenly by frequency: 40 units are 50 Hz and 44 are 60 Hz. A generator's frequency has to match the grid and the equipment it serves. Europe and much of Asia and Africa run on 50 Hz, while North America mainly uses 60 Hz, so the destination usually settles the question. To narrow the list, browse 50 Hz generators or 60 Hz export generators.

Standby ratings range from 8 to 2500 kW. Perkins engines power 60 of the units, Doosan 11, Cummins 10 and Yanmar 3. Each listing offers both an open configuration, for installation inside a building, and an enclosed one, which adds weather and sound protection outdoors. When you send your requirements through the quote form, tell us the destination country and the load.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.