60 HzTier 4 FinalMobile
325 kVA Triton Rental Grade Generator TP-RJD325-T4F-RENTAL Tier 4 Rental
TP-RJD325-T4F-RENTAL
Engine John Deere 6090CG550
- Standby
- 300 kW / 375 kVA
- Prime
- 270 kW / 325 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
Hospitals and other healthcare buildings keep a generator so they can carry on when the utility supply fails, which is the job a standby rating describes.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.
60 HzTier 4 FinalMobile
TP-RJD325-T4F-RENTAL
Engine John Deere 6090CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS350-T4F-RENTAL
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S350-T4F
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P350-T3
Engine Perkins 2206D-E13TAG2
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P350-T3-UL
Engine Perkins 2206D-E13TAG2
Diesel · 60 Hz · Enclosed or open skid
60 HzTier 4 FinalMobile
TP-RS400-T4F-RENTAL
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P400-T3
Engine Perkins 2206D-E13TAG3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P400-T3-UL
Engine Perkins 2206D-E13TAG3
Diesel · 60 Hz · Enclosed or open skid
60 HzUSA EPAMobile
TP-C400-T3-SAE
Engine Cummins QSZ13-G7
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S440-T4F
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS500-T4F-RENTAL
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD440-T4F
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
Not sure which generator you need?
Tell us what you're powering, the destination country, the estimated load and whether it is standby or prime, and our team can help recommend a suitable generator.
60 HzTier 4 FinalMobile
TP-JD500-T4F
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD500-T4F-RENTAL
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P450-T3
Engine Perkins 2506D-E15TAG1
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C450-T3
Engine Cummins QSX15-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P500-T2
Engine Perkins 2506C-E15TAG3L
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P500-T2-UL
Engine Perkins 2506C-E15TAG3L
Diesel · 60 Hz · Enclosed or open skid
60 HzUSA EPAMobile
TP-C500-T3
Engine Cummins QSX15-G9
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V550-T4F
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV625-T4F-RENTAL
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P550-T2
Engine Perkins 2506C-E15TAG4
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P600-T2
Engine Perkins 2806C-E18TAG3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P600-T2-UL
Engine Perkins 2806C-E18TAG3
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS700-T4F-Twin Pack
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V625-T4F
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV713-T4F-RENTAL
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S700-T4F-Twin Pack
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-C800-T1-S-50
Engine Cummins QSK23-G3
Diesel · 50 Hz · Enclosed or open
60 HzUSA EPA
TP-P750-T2-UL
Engine Perkins 2806C-E18TTAG7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C800-T2-60
Engine Cummins QSK23-G7
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S880-T4F-Twin Pack
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS1000-T4F-Twin Pack
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C1000-T2-60
Engine Cummins QST30-G5
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-P1000-T2-S-UL
Engine Perkins 5008C-E30TAG5
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V1100-T4F-Twin Pack
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV1250-T4F-RENTAL TWIN PACK
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV1425-T4F-RENTAL TWIN PACK
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V1250-T4F-Twin Pack
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C1500-T2-60
Engine Cummins QSK50-G4
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C2000-T2-60
Engine Cummins QSK60-G6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C2250-T2-60
Engine Cummins QSK60-G14
Diesel · 60 Hz · Enclosed or open
Showing 24 of 42
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 42 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 42 units here, 1 at 50 Hz and 41 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open, open skid), with dimensions and weights where published. 42 of the 42 units here are offered in more than one configuration. 24 are mobile units.
Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
Hospitals and other healthcare buildings keep a generator so they can carry on when the utility supply fails, which is the job a standby rating describes. The hospital generators in this group are 42 diesel sets with standby ratings from 300 to 2250 kW.
By market label, 21 are Tier 4 Final, 20 are USA EPA-certified and 1 is International (non-EPA, for markets outside the US and Canada). On frequency, 41 run at 60 Hz and 1 runs at 50 Hz, the frequency used in Europe and much of Asia and Africa.
All 42 listings offer an enclosed configuration, 39 also offer an open set and 3 an open skid. An open set suits a dedicated plant room inside the building, while an enclosure adds weather and sound protection outdoors, which can matter on a site close to patient areas. Of the 42 units, 24 are mobile.
Engines are Perkins (12), Scania (9), Cummins (9), Volvo (8) and John Deere (4). If your engineer has issued a specification, include it when you send your requirements through the quote form.
Tell us your required power, destination and application. Our team can help identify the right generator.