100 kW Triton Diesel Generator TP-P100-T1  International Use
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 6 technical documentsspec sheet, engine data, alternator data, brochure
60 Hz International

100 kW Triton Diesel Generator TP-P100-T1 International Use

SKU TP-P100-T1 Model TP-P100-T1-60

Standby rating

100 kW 125 kVA

Prime rating

90 kW 113 kVA

Engine
Perkins 1104C-44TAG2
Alternator
Leroy Somer LSA44.3S5
Control panel
DSE7420
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
110/220 · 120/240 · 120/208 · 277/480
Configuration
Enclosed · Open
Fuel tank
260 L

Market compatibility

International market

Triton International generators are not compliant for use in the United States or Canada due to the emissions status.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.

Markets with a verified 60 Hz grid: Middle East (1) · Caribbean & Central America (7) · Latin America (5) · Asia-Pacific (1) · Countries A–Z

Overview

Product overview

The TP-P100-T1 is a 125 kVA / 100 kW standby, 113 kVA / 90 kW prime diesel generator for international markets.

It uses a Perkins 1104C-44TAG2 engine, a Leroy Somer LSA44.3S5 alternator and a DSE7420 control panel.

It is listed at 60 Hz, 3-phase, with voltages 110/220 and 120/240 and 120/208 and 277/480, in enclosed or open configurations.

  • Powered by Perkins 1104C-44TAG2
  • Emissions: Not EPA Certified – Export Use Only
  • 60 Hz Power Rating at 3 Phase
  • Standby Power Rating: 125 kVA / 100 kW
  • Prime Power Rating: 113 kVA / 90 kW
  • Fuel Capacity 260 L
Read the full product description

We have diesel and natural gas generators from 10 to 10,000 kW. Our International Triton Generators are built to withstand the harsh environment throughout the Caribbean, South America and Africa. Triton generators power everything including Hotels, Marinas, Factories, Warehousing, Government Buildings to full Island Power. Triton Mobile Generators are utilized for their unsurpassed reliability, efficiency, and quiet performance. Triton is the brand you can rely on when you need dependable power.

Our TP-P100-T1-60 provides a standby rating of 100kW / 125kVA and a prime rating of 90kW / 113kVA. The TP-P100-T1-60 is built to rugged specifications and provides the power where and when you need it. By utilizing a Perkins 1104C-44TAG2, this generator set will provide you with unsurpassed performance and reliability.

The TP-P100-T1-60 includes just a few of the following features:
Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open & Enclosed
Sub-Base Tank 8-10 Hours

Triton International generators are not compliant for use in the United States or Canada due to the emissions status. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.

Why choose this model

  • Perkins 1104C-44TAG2 engineEngine data sheet included below
  • Standby & prime rated100 kW / 125 kVA standby · 90 kW / 113 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 110/220, 120/240, 120/208, 277/480
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA44.3S5 alternatorAlternator specifications included below
  • DSE7420 control panelControl panel listed for this model

Typical applications

  • Hotels
  • Marinas
  • Factories
  • Warehousing
  • Government Buildings
  • Island Power

As named in the Triton product description.

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-P100-T1-60
kVA / kW Standby 125 kVA / 100 kW
kVA / kW Prime 113 kVA / 90 kW
Engine
Engine Brand Perkins
Engine Model 1104C-44TAG2
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA44.3S5
Electrical
Voltages Available 110/220, 120/240, 120/208, 277/480
Fuel System
Fuel Tank Capacity 260 L
Control
Control Panel DSE7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsNot EPA Certified – Export Use Only
MarketInternational market
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Compatible with this engine

Parts listed for 1104C-44TAG2

These parts name this engine model in their own description. Confirm your engine serial number when ordering.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-P100-T1 with similar models
ModelTP-P100-T1This model TP-P80-T1TP-P67-T1-S-KTP-P135-T1TP-P60-T1
Standby100 kW / 125 kVA80 kW / 100 kVA67 kW / 85 kVA135 kW / 170 kVA60 kW / 75 kVA
Prime90 kW / 113 kVA73 kW / 91 kVA62 kW / 77 kVA122 kW / 152 kVA55 kW / 68 kVA
EnginePerkins 1104C-44TAG2Perkins 1104A-44TG2Perkins 1104A-44TG1Perkins 1106A-70TG1Perkins 1103A-33TG2
AlternatorLeroy Somer LSA44.3S5Leroy Somer LSA44.3S4Leroy Somer TAL044CLeroy Somer LSA44.3M8*, TAL044HLeroy Somer LSA44.3S2
Control panelDSE7420DSE7420DSE7320DSE7420, DSE7320DSE7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages110/220, 120/240, 120/208, 277/480110/220, 120/240, 120/208, 277/480120/208, 277/480, 110/220, 120/240120/208, 277/480, 120/240110/220, 120/240, 120/208, 277/480
ConfigurationEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, Open
Fuel tank260 L200 L160 L8-10 Hr320 L
MarketInternational marketInternational marketInternational marketInternational marketInternational market
International export support

Buying this generator for an international project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

Supported by Global Generator Supply

+1 251-314-4812

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request