Commercial & Industrial Power Equipment Worldwide

Equipment for use in
1100 kW Triton Diesel Generator TP-V1100-T4F-Twin Pack
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 4 technical documentsspec sheet, engine data, alternator data, brochure
60 Hz Tier 4 Final Mobile

1100 kW Triton Diesel Generator TP-V1100-T4F-Twin Pack

SKU TP-V1100-T4F-Twin Pack

Standby rating

1,100 kW 1,376 kVA

Prime rating

1,000 kW 1,250 kVA

Engine
Volvo TWD1672GE
Alternator
Leroy Somer LSA47.2M8
Control panel
DSE7420
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480 · 120/240
Configuration
Enclosed · Open
Fuel tank
Not specified

Market compatibility

Tier 4 Final

Tier 4 Final EPA-Certified for Nonroad Applications

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-V1100-T4F-Twin Pack is a 1,376 kVA / 1,100 kW standby, 1,250 kVA / 1,000 kW prime diesel generator with a Tier 4 Final emissions configuration.

It uses a Volvo TWD1672GE engine, a Leroy Somer LSA47.2M8 alternator and a DSE7420 control panel.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.

  • Engine: Volvo TWD1672GE
  • Emissions: Tier 4 Final EPA-Certified for Nonroad Applications
  • 60 Hz, three-phase
  • Standby: 1100 kW / 1376 kVA
  • Prime: 1000 kW / 1250 kVA

Triton Tier 4 generators are EPA and CARB compliant and built on a proven platform of emissions control technologies.

Why choose this model

  • Volvo TWD1672GE engineEngine data sheet included below
  • Standby & prime rated1,100 kW / 1,376 kVA standby · 1,000 kW / 1,250 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480, 120/240
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA47.2M8 alternatorAlternator specifications included below
  • DSE7420 control panelControl panel listed for this model

Typical applications

Listed in our industry catalogs: Construction, Customized builds, Data centers, Healthcare, Manufacturing, Military & government, Oil & gas

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-V1100-T4F-Twin Pack
kVA / kW Standby 1376 kVA / 1100 kW
kVA / kW Prime 1250 kVA / 1000 kW
Engine
Engine Brand Volvo
Engine Model TWD1672GE
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA47.2M8
Electrical
Voltages Available 120/208, 277/480, 120/240
Fuel System
Fuel Tank Capacity n/a
Control
Control Panel DSE7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 4 Final EPA-Certified for Nonroad Applications
MarketTier 4 Final
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-V1100-T4F-Twin Pack with similar models
ModelTP-V1100-T4F-Twin PackThis model TP-RV1250-T4F-RENTAL TWIN PACKTP-RV1425-T4F-RENTAL TWIN PACKTP-V1250-T4F-Twin PackTP-S880-T4F-Twin Pack
Standby1,100 kW / 1,376 kVA1,100 kW / 1,376 kVA1,250 kW / 1,568 kVA1,254 kW / 1,568 kVA880 kW / 1,100 kVA
Prime1,000 kW / 1,250 kVA1,000 kW / 1,250 kVA1,140 kW / 1,425 kVA1,140 kW / 1,425 kVA800 kW / 1,000 kVA
EngineVolvo TWD1672GEVolvo TWD1672GEVolvo TWD1673GEVolvo TWD1673GEScania DC16 084A
AlternatorLeroy Somer LSA47.2M8Leroy Somer LSA47.2M8Leroy Somer LSA 47.2 L9Leroy Somer LSA 47.2 L9Leroy Somer LSA47.2S5
Control panelDSE7420DSE7420DSE7420DSE7420XC7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480
ConfigurationEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, Open
Fuel tank————L / Gal
MarketTier 4 FinalTier 4 FinalTier 4 FinalTier 4 FinalTier 4 Final
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request