SKU TP-B3000-T2-60-UL

Standby rating

3,000 kW 3,750 kVA

Prime rating

2,700 kW 3,375 kVA

Engine
Baudoin 16M55G6D2/6
Alternator
Stamford
Control panel
DSE7310
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
277/480
Configuration
Enclosed · Open
Fuel tank
Not specified

Market compatibility

USA EPA-certified

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-B3000-T2-60-UL is a 3,750 kVA / 3,000 kW standby, 3,375 kVA / 2,700 kW prime diesel generator, EPA-certified for the US market.

It uses a Baudoin 16M55G6D2/6 engine, a Stamford alternator and a DSE7310 control panel.

It is listed at 60 Hz, 3-phase, with voltages 277/480, in enclosed or open configurations.

  • Engine: Baudoin 16M55G6D2/6
  • Emissions: Tier 2 EPA Certified Emergency Stationary Applications
  • 60 Hz, three-phase
  • Standby: 3000 kW / 3750 kVA
  • Prime: 2700 kW / 3375 kVA

Why choose this model

  • Baudoin 16M55G6D2/6 engineEngine make and model
  • Standby & prime rated3,000 kW / 3,750 kVA standby · 2,700 kW / 3,375 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 277/480
  • Enclosed or OpenConfigurations available for this model
  • Stamford alternatorAlternator make and model
  • DSE7310 control panelControl panel listed for this model

Typical applications

  • government facilities
  • hotels
  • factories
  • medical facilities
  • grocery stores

As named in the manufacturer's description of this model.

Listed in our industry catalogs: Construction, Customized builds, Manufacturing

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-B3000-T2-60-UL
kVA / kW Standby 3750 kVA / 3000 kW
kVA / kW Prime 3375 kVA / 2700 kW
Engine
Engine Brand Baudoin
Engine Model 16M55G6D2/6
Alternator
Alternator Brand Stamford
Alternator Model Not specified
Electrical
Voltages Available 277/480
Fuel System
Fuel Tank Capacity Not specified
Control
Control Panel DSE7310
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 2 EPA Certified Emergency Stationary Applications
MarketUSA EPA-certified
UL 2200Listed
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

  • Generator Set Specifications Generator set specifications 3000-kw-baudoin-diesel-generator---epa---tp-b3000-t2---16M55G6D2-6.pdf · 256 KB
    Download
  • Product Brochure Product brochure Triton-Power-Product-Brochure.pdf · 5.0 MB
    Download
Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-B3000-T2-60-UL with similar models
ModelTP-B3000-T2-60-ULThis model TP-B3300-T2-60-ULTP-B2500-T2-60-ULTP-C2250-T2-60TP-C2000-T2-60
Standby3,000 kW / 3,750 kVA3,300 kW / 4,125 kVA2,500 kW / 3,125 kVA2,250 kW / 2,825 kVA2,000 kW / 2,500 kVA
Prime2,700 kW / 3,375 kVA2,970 kW / 3,715 kVA2,250 kW / 2,813 kVA1,836 kW / 2,295 kVA1,825 kW / 2,281 kVA
EngineBaudoin 16M55G6D2/6Baudoin 16M55G8D2/6Baudoin 12M55G5D2/6Cummins QSK60-G14Cummins QSK60-G6
AlternatorStamfordStamfordStamfordLeroy Somer LSA52.3S6Leroy Somer LSA52.3S6
Control panelDSE7310DSE7310DSE7310DSE-7420DSE-7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages277/480277/480277/480120/208, 277/480, 120/240120/208, 277/480, 120/240
ConfigurationEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, Open
Fuel tank—————
MarketUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certified
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request