500 kW Triton Diesel Generator TP-JD500-T4F Tier 4 Final

SKU TP-JD500-T4F

Standby rating

440 kW 550 kVA

Prime rating

400 kW 500 kVA

Engine
John Deere 6136CG550
Alternator
Leroy Somer LSA47.3
Control panel
DSE7420
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480 · 120/240
Configuration
Enclosed · Open
Fuel tank
1020 Gal

Market compatibility

Tier 4 Final

Tier 4 Final EPA-Certified for Nonroad Applications

Specifications being verified

Our engineering team is confirming some details on this page (model, standby kw). Please confirm model and ratings with sales before ordering.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-JD500-T4F is a 550 kVA / 440 kW standby, 500 kVA / 400 kW prime diesel generator with a Tier 4 Final emissions configuration.

It uses a John Deere 6136CG550 engine, a Leroy Somer LSA47.3 alternator and a DSE7420 control panel.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.

  • Engine: John Deere 6136CG550
  • Emissions: Tier 4 Final EPA-Certified for Nonroad Applications
  • 60 Hz, three-phase
  • Standby: 440 kW / 550 kVA
  • Prime: 400 kW / 500 kVA
  • Fuel tank: 1020 gal

Triton Tier 4 generators are EPA and CARB-compliant and built on a proven platform of emissions control technologies.

Why choose this model

  • John Deere 6136CG550 engineEngine data sheet included below
  • Standby & prime rated440 kW / 550 kVA standby · 400 kW / 500 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480, 120/240
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA47.3 alternatorAlternator specifications included below
  • DSE7420 control panelControl panel listed for this model

Typical applications

Listed in our industry catalogs: Data centers, Healthcare, Manufacturing, Military & government, Oil & gas, Restaurants & hospitality

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-JD500-T4F
kVA / kW Standby 550 kVA / 440 kW
kVA / kW Prime 500 kVA / 400 kW
Engine
Engine Brand John Deere
Engine Model 6136CG550
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA47.3
Electrical
Voltages Available 120/208, 277/480, 120/240
Fuel System
Fuel Tank Capacity 1020 Gal
Control
Control Panel DSE7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 4 Final EPA-Certified for Nonroad Applications
MarketTier 4 Final
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-JD500-T4F with similar models
ModelTP-JD500-T4FThis model TP-S440-T4FTP-RS500-T4F-RENTALTP-JD440-T4FTP-RJD500-T4F-RENTAL
Standby440 kW / 550 kVA440 kW / 550 kVA440 kW / 550 kVA440 kW / 550 kVA440 kW / 550 kVA
Prime400 kW / 500 kVA400 kW / 500 kVA400 kW / 500 kVA400 kW / 500 kVA400 kW / 500 kVA
EngineJohn Deere 6136CG550Scania DC16 084AScania DC16 084AJohn Deere 6136CG550John Deere 6136CG550
AlternatorLeroy Somer LSA47.3Leroy Somer LSA47.2S5Leroy Somer LSA47.2S5Leroy Somer LSA47.3Leroy Somer LSA47.3S5
Control panelDSE7420DSE7420DSE7420DSE7420DSE7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240
ConfigurationEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, Open
Fuel tank1020 Gal1020L / 269.5Gal1020L / 269.5Gal1020 Gal—
MarketTier 4 FinalTier 4 FinalTier 4 FinalTier 4 FinalTier 4 Final
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request