700 kW Triton Diesel Generator TP-D700-T1 International Use
TP-D700-T1
- Standby
- 705 kW / 882 kVA
- Prime
- 640 kW / 800 kVA
Engine Doosan
Commercial & Industrial Power Equipment Worldwide
SKU TP-P660-T1
Market compatibility
International market
Emissions: Tier 1 Rated, for International Use Only
Triton International generators are not compliant for use in the United States or Canada due to the emissions status.
Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.
Markets with a verified 60 Hz grid: Middle East (1) · Caribbean & Central America (7) · Latin America (5) · Asia-Pacific (1) · Countries A–Z
The TP-P660-T1 is a 825 kVA / 660 kW standby, 750 kVA / 600 kW prime diesel generator for international markets.
It uses a Perkins 4006-23TAG2A engine, a Leroy Somer LSA47.2L9 alternator and a DSE7420 control panel.
It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.
We have diesel and natural gas generators from 10 to 10,000 kW. Our International Triton Generators are built to withstand the harsh environment throughout the Caribbean, South America and Africa. Triton generators power everything including Hotels, Marinas, Factories, Warehousing, Government Buildings to full Island Power. Triton Mobile Generators are utilized for their unsurpassed reliability, efficiency, and quiet performance. Triton is the brand you can rely on when you need dependable power.
Our TP-P660-T1 provides a standby rating of 660kW / 825kVA and a prime rating of 600kW / 750kVA. The TP-P660-T1 is built to rugged specifications and provides the power where and when you need it. By utilizing a Perkins 4006-23TAG2A, this generator set will provide you with Tier 1 EPA standards and also provide unsurpassed performance and reliability.
The TP-P660-T1 includes just a few of the following features:
Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open and Enclosed versions
Sub-Base Tank 8-10 Hours
Triton International generators are not compliant for use in the United States or Canada due to the emissions status. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.
As named in the Triton product description.
Listed in our industry catalogs: Construction, Customized builds, Manufacturing
Values are shown exactly as published. Anything not listed is marked “Not specified”.
Download full specifications| Triton Model | TP-P660-T1 |
|---|---|
| kVA / kW Standby | 825 kVA / 660 kW |
| kVA / kW Prime | 750 kVA / 600 kW |
| Engine Brand | Perkins |
|---|---|
| Engine Model | 4006-23TAG2A |
| Alternator Brand | Leroy Somer |
|---|---|
| Alternator Model | LSA47.2L9 |
| Voltages Available | 120/208, 277/480, 120/240 |
|---|
| Fuel Tank Capacity | 8-10 Hr |
|---|
| Control Panel | DSE7420 |
|---|
| Models Available | Enclosed, Open |
|---|
| Dimensions | Not specified |
|---|---|
| Weight | Not specified |
| Configurations | Enclosed, Open |
Dimensions and weight are not published for this model. Ask for the data sheet.
| Emissions | Tier 1 Rated, for International Use Only |
|---|---|
| Market | International market |
Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.
Our engineers match transfer switches, fuel systems and trailers to this generator's rating when you request a quote.
Same market and frequency, nearest in size. Tick up to three to compare with this model.
TP-D700-T1
Engine Doosan
TP-P600-T1
Engine Perkins
TP-D600-T1
Engine Doosan
TP-P745-T1
Engine Perkins
| Model | TP-P660-T1This model | TP-D700-T1 | TP-P600-T1 | TP-D600-T1 | TP-P745-T1 |
|---|---|---|---|---|---|
| Standby | 660 kW / 825 kVA | 705 kW / 882 kVA | 600 kW / 749 kVA | 600 kW / 750 kVA | 743 kW / 928 kVA |
| Prime | 600 kW / 750 kVA | 640 kW / 800 kVA | 545 kW / 681 kVA | 545 kW / 682 kVA | 675 kW / 844 kVA |
| Engine | Perkins 4006-23TAG2A | Doosan DP222LB | Perkins 2806A-E18TAG3 | Doosan DP180LB | Perkins 4006-23TAG3A |
| Alternator | Leroy Somer LSA47.2L9 | Leroy Somer TAL049C | STAMFORD LSA47.2M8 | Leroy Somer TAL0473F | Leroy Somer LSA49.3M6 |
| Control panel | DSE7420 | DSE7320 | DSE7420 | DSE7320 | DSE7420 |
| Frequency | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
| Voltages | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 |
| Configuration | Enclosed, Open | Enclosed, Open | Enclosed, Open | Enclosed, Open | Enclosed, Open |
| Fuel tank | 8-10 Hr | 1100 Liters (Enclosed) | 8-10 Hr | 970 Liters (Enclosed) | 8-10 Hr |
| Market | International market | International market | International market | International market | International market |
Tick “Compare” on a model above to add it to this table.
Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.