Commercial & Industrial Power Equipment Worldwide

Equipment for use in
80 kW Triton Diesel Generator TP-P80-T3 EPA Certified
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 4 technical documentsspec sheet, engine data, alternator data, brochure
60 Hz USA EPA Tier 3

80 kW Triton Diesel Generator TP-P80-T3 EPA Certified

SKU TP-P80-T3

Standby rating

80 kW 100 kVA

Prime rating

72 kW 90 kVA

Engine
Perkins 1104D-E44TAG1
Alternator
Leroy Somer LSA 44.3 S3
Control panel
DSE7420
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480 · 120/240
Configuration
Enclosed · Open
Fuel tank
Not specified

Market compatibility

USA EPA-certified

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-P80-T3 is a 100 kVA / 80 kW standby, 90 kVA / 72 kW prime diesel generator, EPA-certified for the US market.

It uses a Perkins 1104D-E44TAG1 engine, a Leroy Somer LSA 44.3 S3 alternator and a DSE7420 control panel.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.

  • Engine: Perkins 1104D-E44TAG1
  • Emissions: Tier 3 EPA Certified Emergency Stationary Applications
  • 60 Hz, three-phase
  • Standby: 80 kW / 100 kVA
  • Prime: 72 kW / 90 kVA

Why choose this model

  • Perkins 1104D-E44TAG1 engineEngine data sheet included below
  • Standby & prime rated80 kW / 100 kVA standby · 72 kW / 90 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480, 120/240
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA 44.3 S3 alternatorAlternator specifications included below
  • DSE7420 control panelControl panel listed for this model

Typical applications

  • government facilities
  • hotels
  • factories
  • medical facilities
  • grocery stores

As named in the manufacturer's description of this model.

Listed in our industry catalogs: Restaurants & hospitality

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-P80-T3
kVA / kW Standby 100 kVA / 80 kW
kVA / kW Prime 90 kVA / 72 kW
Engine
Engine Brand Perkins
Engine Model 1104D-E44TAG1
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA 44.3 S3
Electrical
Voltages Available 120/208, 277/480, 120/240
Fuel System
Fuel Tank Capacity N/A
Control
Control Panel DSE7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 3 EPA Certified Emergency Stationary Applications
MarketUSA EPA-certified
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-P80-T3 with similar models
ModelTP-P80-T3This model TP-NG80-S-K-ULTP-P80-T3-ULTP-P65-T3-ULTP-NG100-S-K-UL
Standby80 kW / 100 kVA80 kW / 100 kVA80 kW / 100 kVA65 kW / 81 kVA100 kW / 125 kVA
Prime72 kW / 90 kVA—72 kW / 90 kVA59 kW / 74 kVA—
EnginePerkins 1104D-E44TAG1PSI Engine 5.7LTPerkins 1104D-E44TAG1Perkins 1104D-E44TG1PSI Engine 5.7LT CAC
AlternatorLeroy Somer LSA 44.3 S3—Leroy Somer LSA44.3S3Leroy Somer LSA44.3S4—
Control panelDSE7420—Deep Sea DSE 7420Deep Sea DSE 7420—
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480, 120/240—120/208, 277/480120/208, 277/480—
ConfigurationEnclosed, Open—Enclosed, Open SkidEnclosed, Open Skid—
Fuel tank—————
MarketUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certified
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request