Doosan / Hyundai Mobile Generators

One unit appears under Doosan / Hyundai mobile generators: a Triton diesel set on a Doosan engine, rated 898 kW standby and configured as a mobile unit. It runs at 60 Hz, and its listing shows both open and enclosed configurations.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

1 of 1 generators

Generators

Buyer's guide

Choosing the right generator

Four questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 1 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 1 units here, 1 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 1 of the 1 units here are offered in more than one configuration. 1 are mobile units.

About Doosan / Hyundai Mobile Generators

One unit appears under Doosan / Hyundai mobile generators: a Triton diesel set on a Doosan engine, rated 898 kW standby and configured as a mobile unit. It runs at 60 Hz, and its listing shows both open and enclosed configurations.

Market eligibility for this unit is still being confirmed, so mention where it will be used when you ask about it. The set's frequency also has to suit the local grid and equipment: 60 Hz is the main standard in North America, while 50 Hz is used in Europe and much of Asia and Africa.

Reading the rating

The 898 kW figure is a standby rating, meaning backup power while the utility supply is down. If the set will be the main source of power for long periods with a load that rises and falls, plan around the prime rating instead, which is lower than the standby figure for the same unit. A rating in kVA equals kW divided by the power factor, usually taken as 0.8, and the kW to kVA converter does that arithmetic for you. Send your requirements through the quote form with the expected load.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.