60 HzUSA EPA
40 kW Triton Natural Gas Generator TP-NG40-S-K-UL EPA – UL Listed
TP-NG40-S-K-UL
Engine PSI Engine 4.3L
- Standby
- 40 kW / 50 kVA
- Prime
- 34 kW / 44 kVA
Natural gas / LP · 60 Hz
Commercial & Industrial Power Equipment Worldwide
PSI / GM EPA Generators pair a PSI / GM engine with a Triton generator set intended for the US market. The category holds 4 units; all of them hold the USA EPA-certified label and deliver 60 Hz, the standard frequency across North America.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzUSA EPA
TP-NG40-S-K-UL
Engine PSI Engine 4.3L
Natural gas / LP · 60 Hz
60 HzUSA EPA
TP-NG80-S-K-UL
Engine PSI Engine 5.7LT
Natural gas / LP · 60 Hz
60 HzUSA EPA
TP-NG100-S-K-UL
Engine PSI Engine 5.7LT CAC
Natural gas / LP · 60 Hz
60 HzUSA EPA
TP-NG250-S-K-UL
Engine PSI Engine PSI 13 L
Natural gas / LP · 60 Hz
Showing 4 of 4
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
1 of the 4 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 4 units here, 4 at 60 Hz.
Each unit's page lists the configurations it is offered in, with dimensions and weights where published.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
PSI / GM EPA Generators pair a PSI / GM engine with a Triton generator set intended for the US market. The category holds 4 units; all of them hold the USA EPA-certified label and deliver 60 Hz, the standard frequency across North America.
Since all 4 share the same engine family, the comparison comes down to rating and fuel. The listed numbers are standby ratings, meant for backup power during an outage. Equipment loads are often given in kVA; generators are usually rated at a 0.8 power factor, so multiplying kVA by 0.8 gives the kW to compare, and the kVA to kW calculator does it for you.
For more on gaseous fuel, see natural gas and LP generators. Send your requirements through the quote form.
Tell us your required power, destination and application. Our team can help identify the right generator.