SKU TP-C1000-T2-60

Standby rating

1,000 kW 1,250 kVA

Prime rating

910 kW 1,138 kVA

Engine
Cummins QST30-G5
Alternator
Leroy Somer LSA49.3 L10
Control panel
DSE-7420
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480 · 120/240
Configuration
Enclosed · Open
Fuel tank
Not specified

Market compatibility

USA EPA-certified

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-C1000-T2-60 is a 1,250 kVA / 1,000 kW standby, 1,138 kVA / 910 kW prime diesel generator, EPA-certified for the US market.

It uses a Cummins QST30-G5 engine, a Leroy Somer LSA49.3 L10 alternator and a DSE-7420 control panel.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.

  • Engine: Cummins QST30-G5
  • Emissions: Tier 2 EPA Certified Emergency Stationary Applications
  • 60 Hz, three-phase
  • Standby: 1000 kW / 1250 kVA
  • Prime: 910 kW / 1138 kVA

Why choose this model

  • Cummins QST30-G5 engineEngine data sheet included below
  • Standby & prime rated1,000 kW / 1,250 kVA standby · 910 kW / 1,138 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480, 120/240
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA49.3 L10 alternatorAlternator specifications included below
  • DSE-7420 control panelControl panel listed for this model

Typical applications

  • government facilities
  • hotels
  • factories
  • medical facilities
  • grocery stores

As named in the manufacturer's description of this model.

Listed in our industry catalogs: Construction, Customized builds, Data centers, Healthcare, Manufacturing, Oil & gas

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-C1000-T2-60
kVA / kW Standby 1250 kVA / 1000 kW
kVA / kW Prime 1138 kVA / 910 kW
Engine
Engine Brand Cummins
Engine Model QST30-G5
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA49.3 L10
Electrical
Voltages Available 120/208, 277/480, 120/240
Fuel System
Fuel Tank Capacity n/a
Control
Control Panel DSE-7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 2 EPA Certified Emergency Stationary Applications
MarketUSA EPA-certified
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-C1000-T2-60 with similar models
ModelTP-C1000-T2-60This model TP-P1000-T2-S-ULTP-C800-T2-60TP-P750-T2-ULTP-B1300-T2-60-UL
Standby1,000 kW / 1,250 kVA1,000 kW / 1,250 kVA800 kW / 1,000 kVA750 kW / 937.5 kVA1,300 kW / 1,625 kVA
Prime910 kW / 1,138 kVA900 kW / 1,125 kVA727 kW / 909 kVA675 kW / 844 kVA1,170 kW / 1,462 kVA
EngineCummins QST30-G5Perkins 5008C-E30TAG5Cummins QSK23-G7Perkins 2806C-E18TTAG7Baudoin 12M33G12D2/6
AlternatorLeroy Somer LSA49.3 L10Leroy Somer TAL049ELeroy Somer LSA49.3 M6Leroy Somer TAL049Stamford
Control panelDSE-7420DSE7310DSE-7420DSE7310DSE7310
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240277/480
ConfigurationEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, Open
Fuel tank—————
MarketUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certified
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request