Commercial & Industrial Power Equipment Worldwide

Equipment for use in
1330 kW Triton Diesel Generator TP-P1330-T1  International Use
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 4 technical documentsspec sheet, engine data, alternator data, brochure
60 Hz International Tier 1

1330 kW Triton Diesel Generator TP-P1330-T1 International Use

SKU TP-P1400-T1 Model TP-P1330-T1

Standby rating

1,329 kW 1,669 kVA

Prime rating

1,208 kW 1,510 kVA

Engine
Perkins 4012-46TAG2A
Alternator
Leroy Somer LSA50.2M6
Control panel
DSE7420
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480 · 120/240
Configuration
Enclosed · Open
Fuel tank
8-10 Hr

Market compatibility

International market

Emissions: Tier 1 Rated, for International Use Only

Triton International generators are not compliant for use in the United States or Canada due to the emissions status.

Specifications being verified

Our engineering team is confirming some details on this page (model). Please confirm model and ratings with sales before ordering.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.

Markets with a verified 60 Hz grid: Middle East (1) · Caribbean & Central America (7) · Latin America (5) · Asia-Pacific (1) · Countries A–Z

Overview

Product overview

The TP-P1400-T1 is a 1,669 kVA / 1,329 kW standby, 1,510 kVA / 1,208 kW prime diesel generator for international markets.

It uses a Perkins 4012-46TAG2A engine, a Leroy Somer LSA50.2M6 alternator and a DSE7420 control panel.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.

  • Powered by Perkins 4012-46TAG2A
  • Emissions: Tier 1 Rated, for International Use Only
  • 60 Hz Power Rating at 3 Phase
  • Standby Power Rating: 1669 kVA / 1329 kW
  • Prime Power Rating: 1510 kVA / 1208 kW
  • Fuel Capacity 8-10 Hr
Read the full product description

We have diesel and natural gas generators from 10 to 10,000 kW. Our International Triton Generators are built to withstand the harsh environment throughout the Caribbean, South America and Africa. Triton generators power everything including Hotels, Marinas, Factories, Warehousing, Government Buildings to full Island Power. Triton Mobile Generators are utilized for their unsurpassed reliability, efficiency, and quiet performance. Triton is the brand you can rely on when you need dependable power.

Our TP-P1330-T1 provides a standby rating of 1329kW / 1669kVA and a prime rating of 1208kW / 1510kVA. The TP-P1330-T1 is built to rugged specifications and provides the power where and when you need it. By utilizing a Perkins 4012-46TAG2A, this generator set will provide you with Tier 1 EPA standards and also provide unsurpassed performance and reliability.

The TP-P1330-T1 includes just a few of the following features:

Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open and Enclosed versions
Sub-Base Tank 8-10 Hours

Triton International generators are not compliant for use in the United States or Canada due to the emissions status. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.

Why choose this model

  • Perkins 4012-46TAG2A engineEngine data sheet included below
  • Standby & prime rated1,329 kW / 1,669 kVA standby · 1,208 kW / 1,510 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480, 120/240
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA50.2M6 alternatorAlternator specifications included below
  • DSE7420 control panelControl panel listed for this model

Typical applications

  • Hotels
  • Marinas
  • Factories
  • Warehousing
  • Government Buildings
  • Island Power

As named in the Triton product description.

Listed in our industry catalogs: Construction, Customized builds, Manufacturing

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-P1330-T1
kVA / kW Standby 1669 kVA / 1329 kW
kVA / kW Prime 1510 kVA / 1208 kW
Engine
Engine Brand Perkins
Engine Model 4012-46TAG2A
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA50.2M6
Electrical
Voltages Available 120/208, 277/480, 120/240
Fuel System
Fuel Tank Capacity 8-10 Hr
Control
Control Panel DSE7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 1 Rated, for International Use Only
MarketInternational market
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-P1400-T1 with similar models
ModelTP-P1400-T1This model TP-CK1250-T1-C-60TP-P1200-T1-60TP-C1500-T1-CTP-P1100-T1
Standby1,329 kW / 1,669 kVA1,262 kW / 1,578 kVA1,200 kW / 1,500 kVA1,500 kW / 1,875 kVA1,102 kW / 1,378 kVA
Prime1,208 kW / 1,510 kVA1,123 kW / 1,404 kVA1,092 kW / 1,364 kVA1,250 kW / 1,562 kVA1,002 kW / 1,253 kVA
EnginePerkins 4012-46TAG2ACummins KTA50-G3Perkins 4012-46TWG3ACummins KTA50-G9Perkins 4012-46TWG2A
AlternatorLeroy Somer LSA50.2M6Leroy Somer LSA49.3 L10Leroy Somer LSA50.2M6Leroy Somer LSA 50.2 M6Leroy Somer LSA49.3L10
Control panelDSE7420DSE 7320DSE7420DSE7420DSE7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480, 120/240
ConfigurationEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, Open
Fuel tank8-10 Hr8-10 Hours—8-10 Hours8-10 Hr
MarketInternational marketInternational marketInternational marketInternational marketInternational market
International export support

Buying this generator for an international project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

Supported by Global Generator Supply

+1 251-314-4812

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request