- Export supportconfiguration and shipping quotes for your destination
- Engineering supporthelp with sizing, voltage and configuration
- 6 technical documentsspec sheet, engine data, alternator data, brochure
150 kVA Triton Diesel Generator TP-P150-T1-50 International Use
SKU TP-P165-T1-50 Model TP-P150-T1-50
- Engine
- Perkins 1106A-70TAG2
- Alternator
- Leroy Somer LSA44.3VL14
- Control panel
- DSE7420
- Fuel
- Diesel
- Frequency / phase
- 50 Hz · 3-phase
- Voltages listed
- 110/220 · 240/380
- Configuration
- Enclosed · Open
- Fuel tank
- 8-10 Hr
Market compatibility
International market
Emissions: Tier 1 Rated, for International Use Only
Triton International generators are not compliant for use in the United States or Canada due to the emissions status.
Our engineering team is confirming some details on this page (model). Please confirm model and ratings with sales before ordering.
Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.
Markets with a verified 50 Hz grid: Africa (13) · Middle East (5) · Caribbean & Central America (1) · Latin America (3) · Asia-Pacific (7) · Countries A–Z
Product overview
The TP-P165-T1-50 is a 165 kVA / 132 kW standby, 150 kVA / 120 kW prime diesel generator for international markets.
It uses a Perkins 1106A-70TAG2 engine, a Leroy Somer LSA44.3VL14 alternator and a DSE7420 control panel.
It is listed at 50 Hz, 3-phase, with voltages 110/220 and 240/380, in enclosed or open configurations.
- Powered by Perkins 1106A-70TAG2
- Emissions: Tier 1 Rated, for International Use Only
- 50 Hz Power Rating at 3 Phase
- Standby Power Rating: 165 kVA / 132 kW
- Prime Power Rating: 150 kVA / 120 kW
- Fuel Capacity 8-10 Hr
Read the full product description
We have diesel and natural gas generators from 10 to 10,000 kW. Our International Triton Generators are built to withstand the harsh environment throughout the Caribbean, South America and Africa. Triton generators power everything including Hotels, Marinas, Factories, Warehousing, Government Buildings to full Island Power. Triton Mobile Generators are utilized for their unsurpassed reliability, efficiency, and quiet performance. Triton is the brand you can rely on when you need dependable power.
Our TP-P150-T1-50 provides a standby rating of 132kW / 165kVA and a prime rating of 120kW / 150kVA. The TP-P150-T1-50 is built to rugged specifications and provides the power where and when you need it. By utilizing a Perkins 1106A-70TAG2, this generator set will provide you with the stringent EPA standards and also provide unsurpassed performance and reliability.
The TP-P150-T1-50 includes just a few of the following features:
Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open & Enclosed
Sub-Base Tank 8-10 Hours
Triton International generators are not compliant for use in the United States or Canada due to the emissions status. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.
Why choose this model
- Perkins 1106A-70TAG2 engineEngine data sheet included below
- Standby & prime rated165 kVA / 132 kW standby · 150 kVA / 120 kW prime
- 50 Hz, 3-phaseVoltages listed: 110/220, 240/380
- Enclosed or OpenConfigurations available for this model
- Leroy Somer LSA44.3VL14 alternatorAlternator specifications included below
- DSE7420 control panelControl panel listed for this model
Typical applications
- Hotels
- Marinas
- Factories
- Warehousing
- Government Buildings
- Island Power
As named in the Triton product description.
Specifications
Values are shown exactly as published. Anything not listed is marked “Not specified”.
Download full specifications| Triton Model | TP-P150-T1-50 |
|---|---|
| kVA / kW Standby | 165 kVA / 132 kW |
| kVA / kW Prime | 150 kVA / 120 kW |
| Engine Brand | Perkins |
|---|---|
| Engine Model | 1106A-70TAG2 |
| Alternator Brand | Leroy Somer |
|---|---|
| Alternator Model | LSA44.3VL14 |
| Voltages Available | 110/220, 240/380 |
|---|
| Fuel Tank Capacity | 8-10 Hr |
|---|
| Control Panel | DSE7420 |
|---|
| Models Available | Enclosed, Open |
|---|
| Dimensions | Not specified |
|---|---|
| Weight | Not specified |
| Configurations | Enclosed, Open |
Dimensions and weight are not published for this model. Ask for the data sheet.
| Emissions | Tier 1 Rated, for International Use Only |
|---|---|
| Market | International market |
Technical documents
Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.
- Generator Set Specifications V1 Generator set specificationsDownload
- Generator Set Specifications V2 Generator set specificationsDownload
- Engine Data Sheet Engine data sheetDownload
- Alternator Specifications V1 Alternator specificationsDownload
- Alternator Specifications V2 Alternator specificationsDownload
- Product Brochure Product brochureDownload
Parts listed for 1106A-70TAG2
These parts name this engine model in their own description. Confirm your engine serial number when ordering.
Everything this unit needs on site
Our engineers match transfer switches, fuel systems and trailers to this generator's rating when you request a quote.
- Automatic transfer switchAutomatic transfer switches from 100 to 4,000 A. Matched to this unit on request View transfer switches
- Fuel systemListed with this model: 8-10 Hr. 16 double wall and 19 single wall tanks, UL 142 and non-UL. Matched to this unit on request View fuel tanks
- TrailerOpen-deck and generator trailers. Matched to this unit on request View trailers
- Parts for the 1106A-70TAG23 parts name this engine model in their own description. Compatible with this engine See compatible parts
Compare with similar models
Same market and frequency, nearest in size. Tick up to three to compare with this model.
- 50 Hz International
135 kVA Triton Diesel Generator TP-P135-T1-50 International Use
TP-P150-T1-50
- Standby
- 120 kW / 150 kVA
- Prime
- 108 kW / 135 kVA
Engine Perkins
- 50 Hz International
200 kVA Triton Diesel Generator TP-P175-T1-50 International Use
TP-P200-T1-50
- Standby
- 158 kW / 198 kVA
- Prime
- 144 kW / 180 kVA
Engine Perkins
- 50 Hz International
100 kVA Triton Diesel Generator TP-P100-T1-50 International Use
TP-P110-T1-50
- Standby
- 89 kW / 110 kVA
- Prime
- 80 kW / 100 kVA
Engine Perkins
- 50 Hz International
80 kVA Triton Diesel Generator TP-P80-T1-50 International Use
TP-P88-T1-50
- Standby
- 70 kW / 88 kVA
- Prime
- 64 kW / 80 kVA
Engine Perkins
| Model | TP-P165-T1-50This model | TP-P150-T1-50 | TP-P200-T1-50 | TP-P110-T1-50 | TP-P88-T1-50 |
|---|---|---|---|---|---|
| Standby | 165 kVA / 132 kW | 150 kVA / 120 kW | 198 kVA / 158 kW | 110 kVA / 89 kW | 88 kVA / 70 kW |
| Prime | 150 kVA / 120 kW | 135 kVA / 108 kW | 180 kVA / 144 kW | 100 kVA / 80 kW | 80 kVA / 64 kW |
| Engine | Perkins 1106A-70TAG2 | Perkins 1106A-70TG1 | Perkins 1106A-70TAG3 | Perkins 1104C-44TAG2 | Perkins 1104A-44TG2 |
| Alternator | Leroy Somer LSA44.3VL14 | Leroy Somer LSA44.3M8 | Leroy Somer LSA44.3VL13 | Leroy Somer LSA44.3S5 | Leroy Somer LSA44.3S4 |
| Control panel | DSE7420 | — | DSE7420 | DSE7420 | DSE7420 |
| Frequency | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz |
| Voltages | 110/220, 240/380 | 110/220, 240/380 | 110/220, 240/380 | 110/220, 240/380 | 110/220, 240/380 |
| Configuration | Enclosed, Open | Enclosed, Open | Enclosed, Open | Enclosed, Open | Enclosed, Open |
| Fuel tank | 8-10 Hr | 8-10 Hr | 8-10 Hr | 260 L | 200 L |
| Market | International market | International market | International market | International market | International market |
Tick “Compare” on a model above to add it to this table.
Buying this generator for an international project?
Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.
Supported by Global Generator Supply
- Engineeringhelp with sizing, voltage and configuration
- Export supportdocuments and shipping quotes on request
- Partsparts and components for your equipment
- Quote listcombine several products in one request