150 kW Triton Diesel Generator TP-P150-T1 International Use
TP-P150-T1
- Standby
- 150 kW / 187 kVA
- Prime
- 135 kW / 170 kVA
Engine Perkins
Market eligibility being confirmed
Commercial & Industrial Power Equipment Worldwide
SKU TP-P200-T3
Market compatibility
Eligibility being confirmed
Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.
Our team is confirming which markets this unit can be used in. Contact sales before ordering.
Our engineering team is confirming some details on this page (market eligibility, ul2200). Please confirm model and ratings with sales before ordering.
Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.
The TP-P200-T3 is a 250 kVA / 200 kW standby, 225 kVA / 180 kW prime diesel generator.
It uses a Perkins 1106D-E70TAG5 engine, a Leroy Somer LSA46.3S4 alternator and a DSE7420 control panel.
It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.
As named in the manufacturer's description of this model.
Listed in our industry catalogs: Data centers, Manufacturing, Restaurants & hospitality
Values are shown exactly as published. Anything not listed is marked “Not specified”.
Download full specifications| Triton Model | TP-P200-T3 |
|---|---|
| kVA / kW Standby | 250 kVA / 200 kW |
| kVA / kW Prime | 225 kVA / 180 kW |
| Engine Brand | Perkins |
|---|---|
| Engine Model | 1106D-E70TAG5 |
| Alternator Brand | Leroy Somer |
|---|---|
| Alternator Model | LSA46.3S4 |
| Voltages Available | 120/208, 277/480, 120/240 |
|---|
| Fuel Tank Capacity | n/a |
|---|
| Control Panel | DSE7420 |
|---|
| Models Available | Enclosed, Open |
|---|
| Dimensions | Not specified |
|---|---|
| Weight | Not specified |
| Configurations | Enclosed, Open |
Dimensions and weight are not published for this model. Ask for the data sheet.
| Emissions | Tier 3 EPA Certified Emergency Stationary Applications |
|---|---|
| Market | Eligibility being confirmed |
Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.
Our engineers match transfer switches, fuel systems and trailers to this generator's rating when you request a quote.
Same market and frequency, nearest in size. Tick up to three to compare with this model.
TP-P150-T1
Engine Perkins
Market eligibility being confirmed
TP-65-T3
Engine Perkins
Market eligibility being confirmed
TP-D800-T2-UL
Engine Doosan
Market eligibility being confirmed
TP-D900-T2-UL
Engine Doosan
Market eligibility being confirmed
| Model | TP-P200-T3This model | TP-P150-T1 | TP-P65-T3 | TP-D800-T2-UL | TP-D900-T2-UL |
|---|---|---|---|---|---|
| Standby | 200 kW / 250 kVA | 150 kW / 187 kVA | 65 kW / 81 kVA | 800 kW / 1,000 kVA | 898 kW / 1,123 kVA |
| Prime | 180 kW / 225 kVA | 135 kW / 170 kVA | 59 kW / 74 kVA | 728 kW / 910 kVA | 812 kW / 1,015 kVA |
| Engine | Perkins 1106D-E70TAG5 | Perkins 1106A-70TAG2 | Perkins 1104D-E44TG1 | Doosan DP222CB | Doosan DP222CC |
| Alternator | Leroy Somer LSA46.3S4 | Leroy Somer LSA44.3L10, TAL044J | — | Leroy Somer TAL049C | Leroy Somer TAL049C |
| Control panel | DSE7420 | DSE7420, DSE7320 | — | DSE | DSE |
| Frequency | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
| Voltages | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 |
| Configuration | Enclosed, Open | Enclosed, Open | Enclosed, Open | Enclosed, Open | Enclosed, Open |
| Fuel tank | — | 8-10 Hr | — | 1100 Liters (Enclosed) | 1100 Liters (Enclosed) |
| Market | Eligibility being confirmed | Eligibility being confirmed | Eligibility being confirmed | Eligibility being confirmed | Eligibility being confirmed |
Tick “Compare” on a model above to add it to this table.
Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.