29 kW Triton Diesel Generator TP-P29-T4i EPA Certified
TP-29-T4i
- Standby
- 29 kW / 37 kVA
- Prime
- 27 kW / 35 kVA
Engine Perkins
Commercial & Industrial Power Equipment Worldwide
SKU TP-Y30-T4i-SGUL
Market compatibility
USA EPA-certified
Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.
Our engineering team is confirming some details on this page (prime kva). Please confirm model and ratings with sales before ordering.
Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.
The TP-Y30-T4i-SGUL is a 37.5 kVA / 30 kW standby, 34 kVA / 27 kW prime diesel generator, EPA-certified for the US market.
It uses a Yanmar 4TNV98T engine, a Stamford or Leroy Somer alternator.
It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed configurations.
Global Generator Supply provides Emergency Stationary generators that are certified to Tier 4i, 3 and 2 depending upon the generator rating required. We provide UL2200, CSA and other certifications. Triton can build nearly any type of generator for your requirements, including both gaseous and diesel generators. Further, we maintain a stock of generators built to standard specifications for immediate shipment, including trailers, transfer switches and fuel tanks.
Triton EPA Generators are to exacting standards for the US and Canadian markets. We provide options for everything from hurricane zones to the harsh environment of the far north. Triton Generators are used at a variety of locations including government facilities, hotels, factories, medical facilities and grocery stores.
Our TP-Y30-T4i-SGUL provides a standby rating of 30kW / 37.5kVA and a prime rating of 27kW / 34kVA. The TP-Y30-T4i-SGUL is built to rugged specifications and provides the power where and when you need it. By utilizing a Yanmar 4TNV98T, this generator set will provide you with the EPA standards and also provide unsurpassed performance and reliability.
The TP-Y30-T4i-SGUL includes just a few of the following features:
Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open and Enclosed
Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.
Listed in our industry catalogs: Restaurants & hospitality
Values are shown exactly as published. Anything not listed is marked “Not specified”.
Download full specifications| Triton Model | TP-Y30-T4i-SGUL |
|---|---|
| kVA / kW Standby | 37.5 kVA / 30 kW |
| kVA / kW Prime | 34 kVA / 27 kW |
| Engine Brand | Yanmar |
|---|---|
| Engine Model | 4TNV98T |
| Alternator Brand | Stamford or Leroy Somer |
|---|---|
| Alternator Model | N/A |
| Voltages Available | 120/208, 277/480, 120/240 |
|---|
| Fuel Tank Capacity | N/A |
|---|
| Control Panel | N/A |
|---|
| Models Available | Enclosed |
|---|
| Dimensions | Not specified |
|---|---|
| Weight | Not specified |
| Configurations | Enclosed |
Dimensions and weight are not published for this model. Ask for the data sheet.
| Emissions | Tier 4i EPA Certified Emergency Stationary Applications |
|---|---|
| Market | USA EPA-certified |
| UL 2200 | Listed |
Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.
Our engineers match transfer switches, fuel systems and trailers to this generator's rating when you request a quote.
Same market and frequency, nearest in size. Tick up to three to compare with this model.
TP-29-T4i
Engine Perkins
TP-P30-T4i-UL
Engine Perkins
TP-Y40-T4i-SGUL
Engine Yanmar
TP-20-T4i
Engine Perkins
| Model | TP-Y30-T4i-SGULThis model | TP-29-T4i | TP-P30-T4i-UL | TP-Y40-T4i-SGUL | TP-20-T4i |
|---|---|---|---|---|---|
| Standby | 30 kW / 37.5 kVA | 29 kW / 37 kVA | 29 kW / 37 kVA | 38 kW / 47 kVA | 20 kW / 26 kVA |
| Prime | 27 kW / 34 kVA | 27 kW / 35 kVA | 27 kW / 35 kVA | 34 kW / 40 kVA | 18 kW / 24 kVA |
| Engine | Yanmar 4TNV98T | Perkins 404D-22TG | Perkins 404D-22TG | Yanmar 4TNV98T | Perkins 404D-22G |
| Alternator | Stamford or Leroy Somer | Leroy Somer LSA 42.3 VS2 | Leroy Somer LSA42.3-VS2 | Stamford | Leroy Somer LSA 40 M5 |
| Control panel | — | DSE7420 | Deep Sea DSE 7420 | — | DSE7420 |
| Frequency | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
| Voltages | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 | 120/208, 277/480 | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 |
| Configuration | Enclosed | Enclosed, Open | Enclosed, Open Skid | Enclosed, Open | Enclosed, Open |
| Fuel tank | — | — | — | — | — |
| Market | USA EPA-certified | USA EPA-certified | USA EPA-certified | USA EPA-certified | USA EPA-certified |
Tick “Compare” on a model above to add it to this table.
Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.