Commercial & Industrial Power Equipment Worldwide

Equipment for use in
40 kW Triton Diesel Generator TP-Y40-T4i-SGUL Tier 4i – UL Listed
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 2 technical documentsspec sheet, brochure
60 Hz USA EPA Tier 4i UL2200

40 kW Triton Diesel Generator TP-Y40-T4i-SGUL Tier 4i – UL Listed

SKU TP-Y40-T4i-SGUL

Standby rating

38 kW 47 kVA

Prime rating

34 kW 40 kVA

Engine
Yanmar 4TNV98T
Alternator
Stamford
Control panel
Not specified
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480 · 120/240
Configuration
Enclosed · Open
Fuel tank
Not specified

Market compatibility

USA EPA-certified

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-Y40-T4i-SGUL is a 47 kVA / 38 kW standby, 40 kVA / 34 kW prime diesel generator, EPA-certified for the US market.

It uses a Yanmar 4TNV98T engine, a Stamford alternator.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.

  • Powered by Yanmar 4TNV98T
  • Emissions: Tier 4i EPA Certified Emergency Stationary Applications
  • 60 Hz Power Rating at 3 Phase
  • Standby Power Rating: 47 kVA / 38 kW
  • Prime Power Rating: 40 kVA / 34 kW
Read the full product description

Global Generator Supply provides Emergency Stationary generators that are certified to Tier 4i, 3 and 2 depending upon the generator rating required. We provide UL2200, CSA and other certifications. Triton can build nearly any type of generator for your requirements, including both gaseous and diesel generators. Further, we maintain a stock of generators built to standard specifications for immediate shipment, including trailers, transfer switches and fuel tanks.

Triton EPA Generators are to exacting standards for the US and Canadian markets. We provide options for everything from hurricane zones to the harsh environment of the far north. Triton Generators are used at a variety of locations including government facilities, hotels, factories, medical facilities and grocery stores.

Our TP-Y40-T4i-SGUL provides a standby rating of 38kW / 47kVA and a prime rating of 34kW / 40kVA. The TP-Y40-T4i-SGUL is built to rugged specifications and provides the power where and when you need it. By utilizing a Yanmar 4TNV98T, this generator set will provide you with the EPA standards and also provide unsurpassed performance and reliability.

The TP-Y40-T4i-SGUL includes just a few of the following features:

Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open and Enclosed

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.

Why choose this model

  • Yanmar 4TNV98T engineEngine make and model
  • Standby & prime rated38 kW / 47 kVA standby · 34 kW / 40 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480, 120/240
  • Enclosed or OpenConfigurations available for this model
  • Stamford alternatorAlternator make and model

Typical applications

Listed in our industry catalogs: Restaurants & hospitality

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-Y40-T4i-SGUL
kVA / kW Standby 47 kVA / 38 kW
kVA / kW Prime 40 kVA / 34 kW
Engine
Engine Brand Yanmar
Engine Model 4TNV98T
Alternator
Alternator Brand Stamford
Alternator Model N/A
Electrical
Voltages Available 120/208, 277/480, 120/240
Fuel System
Fuel Tank Capacity N/A
Control
Control Panel N/A
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 4i EPA Certified Emergency Stationary Applications
MarketUSA EPA-certified
UL 2200Listed
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

  • Generator Set Specifications Generator set specifications 40-kw-yanmar-diesel-generator-epa---tp-y40-t4i-ul.pdf · 359 KB
    Download
  • Product Brochure Product brochure Triton-Power-Product-Brochure.pdf · 5.0 MB
    Download
Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-Y40-T4i-SGUL with similar models
ModelTP-Y40-T4i-SGULThis model TP-NG40-S-K-ULTP-Y30-T4i-SGULTP-29-T4iTP-P30-T4i-UL
Standby38 kW / 47 kVA40 kW / 50 kVA30 kW / 37.5 kVA29 kW / 37 kVA29 kW / 37 kVA
Prime34 kW / 40 kVA34 kW / 44 kVA27 kW / 34 kVA27 kW / 35 kVA27 kW / 35 kVA
EngineYanmar 4TNV98TPSI Engine 4.3LYanmar 4TNV98TPerkins 404D-22TGPerkins 404D-22TG
AlternatorStamford—Stamford or Leroy SomerLeroy Somer LSA 42.3 VS2Leroy Somer LSA42.3-VS2
Control panel———DSE7420Deep Sea DSE 7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480, 120/240—120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480
ConfigurationEnclosed, Open—EnclosedEnclosed, OpenEnclosed, Open Skid
Fuel tank—————
MarketUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certified
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

Supported by Global Generator Supply

+1 251-314-4812

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request