Generator Engine Oil: Changes, Checks and Care

· 2 min read

Tips for Generator Oil Changes and Maintenance

Looking after the oil is one of the simplest ways to make sure a generator runs dependably when you call on it. The tips below cover everything from installation to routine oil changes and will help keep the engine well lubricated and running smoothly.

  1. After the generator is installed, check its oil level. It may have arrived with no oil in it, and if the installer did not fill it, you will have to do so yourself.
  2. Follow the manufacturer's recommendations on oil type every time. The right oil differs from one generator to the next, depending on its engine and the fuel it uses.
  3. Think about the temperatures the generator will run in. Cold conditions call for a lower-viscosity oil, while hot conditions call for a higher-viscosity one. Perkins' operation manuals advise generally choosing the highest viscosity oil available that still satisfies the start-up temperature requirement.
  4. The first oil change comes earlier than the ones that follow. Check the owner's manual for the exact number of hours before that first change; it can be as early as eight hours into the break-in period.
  5. Change the oil on a regular schedule, following the interval in the owner's manual. Smaller gas generators may need fresh oil as frequently as once every 50 hours, while large diesel generators may go as long as 500 hours between changes.
  6. Where the generator has an oil filter, replace it whenever you change the oil.
  7. Each time you refuel, top up the oil reservoir if it needs it.
  8. Keep spare oil and filters on hand so you can keep up with oil changes during outages, when the generator may run for hundreds of hours without stopping.
  9. Factor in the environment the generator operates in when deciding when to change the oil. On dusty job sites the oil gets dirty faster and should be changed more often than oil that is not exposed to large airborne particles.
  10. Once a long outage is over and the generator has run for an extended period, check the oil level and change the oil if needed. That way the generator is ready the next time you depend on it.
  11. To protect the engine, many generators shut down on their own when the oil runs low. If the generator is not working as it should, check the oil reservoir and top it up or change the oil before doing any further diagnosis.
  12. Whenever you check the oil level or change the oil, clean dirt and debris away from the area first.