The charger's connection points on the control panel differ from one generator model to another. The examples below cover several terminal block types that Triton Generators commonly use.

This connection is usually found on Perkins UL2200 Generators and certain Perkins and Doosan Export Generator Sets. The position of the terminal block may vary based on the generator size. The battery charger will connect to the control panel on terminal block

1. Perkins UL2200 Generators typically use this arrangement, as do some Doosan and Perkins Export Generator Sets. Where the terminal block sits can change with the size of the generator. Here the charger wires land on terminal block “X2”, at terminals #1 and #2.

2. This connection is usually found on Tier 4 Final Generators and certain Perkins and Cummins Generator Sets. The position of the terminal block may vary based on the generator size. The battery charger will connect to the control panel using wire #5 and wire #8, labeled as

2. Tier 4 Final Generators typically use this arrangement, along with some Cummins and Perkins Generator Sets. Again, the block's position depends on how large the generator is. On the control panel, the charger attaches to wires #5 and #8, which are marked “55” and “58”.

3. This connection can be found on UL2200 Generators powered by Volvo, John Deere or Mitsubishi engines. It can also be found in Natural Gas Generators and certain Cummins Export-Only Generator Sets. The position of the terminal block may vary based on the generator size. The battery charger will connect to the control panel using terminals

3. Look for this arrangement on UL2200 Generators with Mitsubishi, Volvo or John Deere engines, on Natural Gas Generators and on some Cummins Export-Only Generator Sets. As with the others, the terminal block's location depends on generator size. The charger is wired to the terminals marked “L” and “N” on the control panel, as the photo shows.