100 kW Triton Diesel Generator TP-P100-T3 EPA Certified
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 4 technical documentsspec sheet, engine data, alternator data, brochure
60 Hz USA EPA Tier 3

100 kW Triton Diesel Generator TP-P100-T3 EPA Certified

SKU TP-P100-T3

Standby rating

100 kW 125 kVA

Prime rating

90 kW 113 kVA

Engine
Perkins 1104D-E44TAG2
Alternator
Leroy Somer LSA44.3S5
Control panel
DSE7420
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480 · 120/240
Configuration
Enclosed · Open
Fuel tank
Not specified

Market compatibility

USA EPA-certified

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-P100-T3 is a 125 kVA / 100 kW standby, 113 kVA / 90 kW prime diesel generator, EPA-certified for the US market.

It uses a Perkins 1104D-E44TAG2 engine, a Leroy Somer LSA44.3S5 alternator and a DSE7420 control panel.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.

  • Powered by Perkins 1104D-E44TAG2
  • Emissions: Tier 3 EPA Certified Emergency Stationary Applications
  • 60 Hz Power Rating at 3 Phase
  • Standby Power Rating: 125 kVA / 100 kW
  • Prime Power Rating: 113 kVA / 90 kW
Read the full product description

Global Generator Supply provides Emergency Stationary generators that are certified to Tier 4i, 3 and 2 depending upon the generator rating required. We provide UL2200, CSA and other certifications. Triton can build nearly any type of generator for your requirements, including both gaseous and diesel generators. Further, we maintain a stock of generators built to standard specifications for immediate shipment, including trailers, transfer switches and fuel tanks.

Triton EPA Generators are to exacting standards for the US and Canadian markets. We provide options for everything from hurricane zones to the harsh environment of the far north. Triton Generators are used at a variety of locations including government facilities, hotels, factories, medical facilities and grocery stores.

Our TP-P100-T3 provides a standby rating of 100kW / 125kVA and a prime rating of 90kW / 113kVA. The TP-P100-T3 is built to rugged specifications and provides the power where and when you need it. By utilizing a Perkins engine model 1104D-E44TAG2, this generator set will provide you with the EPA standards and also provide unsurpassed performance and reliability.

The TP-P100-T3 includes just a few of the following features:

Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open and Enclosed
8 to 10 Hours Fuel Tank

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.

Why choose this model

  • Perkins 1104D-E44TAG2 engineEngine data sheet included below
  • Standby & prime rated100 kW / 125 kVA standby · 90 kW / 113 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480, 120/240
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA44.3S5 alternatorAlternator specifications included below
  • DSE7420 control panelControl panel listed for this model

Typical applications

Listed in our industry catalogs: Data centers, Restaurants & hospitality

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-P100-T3
kVA / kW Standby 125 kVA / 100 kW
kVA / kW Prime 113 kVA / 90 kW
Engine
Engine Brand Perkins
Engine Model 1104D-E44TAG2
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA44.3S5
Electrical
Voltages Available 120/208, 277/480, 120/240
Fuel System
Fuel Tank Capacity N/A
Control
Control Panel DSE7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 3 EPA Certified Emergency Stationary Applications
MarketUSA EPA-certified
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Compatible with this engine

Parts listed for 1104D-E44TAG2

These parts name this engine model in their own description. Confirm your engine serial number when ordering.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-P100-T3 with similar models
ModelTP-P100-T3This model TP-NG100-S-K-ULTP-P100-T3-ULTP-NG80-S-K-ULTP-P80-T3
Standby100 kW / 125 kVA100 kW / 125 kVA100 kW / 125 kVA80 kW / 100 kVA80 kW / 100 kVA
Prime90 kW / 113 kVA—90 kW / 113 kVA—72 kW / 90 kVA
EnginePerkins 1104D-E44TAG2PSI Engine 5.7LT CACPerkins 1104D-E44TAG2PSI Engine 5.7LTPerkins 1104D-E44TAG1
AlternatorLeroy Somer LSA44.3S5—Leroy Somer LSA44.3S5—Leroy Somer LSA 44.3 S3
Control panelDSE7420—Deep Sea DSE 7420—DSE7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480, 120/240—120/208, 277/480—120/208, 277/480, 120/240
ConfigurationEnclosed, Open—Enclosed, Open Skid—Enclosed, Open
Fuel tank—————
MarketUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certified
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

Supported by Global Generator Supply

+1 251-314-4812

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request