Commercial & Industrial Power Equipment Worldwide
SKU TP-P100-T3-UL
Market compatibility
USA EPA-certified
Tier 3 EPA Certified — Emergency Stationary Applications · Tier 3 – UL Listed
Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.
The TP-P100-T3-UL is a 125 kVA / 100 kW standby, 113 kVA / 90 kW prime diesel generator, EPA-certified for the US market.
It uses a Perkins 1104D-E44TAG2 engine, a Leroy Somer LSA44.3S5 alternator and a Deep Sea DSE 7420 control panel.
It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480, in enclosed or open skid configurations.
Global Generator Supply provides Emergency Stationary generators certified to Tier 4i, Tier 3, and Tier 2 ratings, with UL2200, CSA, and other compliance options. Triton can build virtually any generator to spec — gaseous or diesel — and we maintain ready stock of generators built to standard configurations for immediate shipment, along with trailers, transfer switches, and fuel tanks.
Triton EPA Generators are engineered to exacting standards for the US and Canadian markets. We offer options for everything from hurricane zones along the Gulf coast to the harsh climate of the far north. Triton generators are deployed at government facilities, hotels, manufacturing plants, medical facilities, grocery stores, and data centers across North America.
The TP-P100-T3-UL delivers a standby rating of 100 kW / 125 kVA and a prime rating of 90 kW / 113 kVA. The Perkins 1104D-E44TAG2 is a four-cylinder, turbocharged and air-to-air aftercooled diesel engine engineered for higher-output performance and Tier 3 emissions compliance in demanding power generation applications. Operating at 1800 rpm, it delivers 117 kWm (156.8 hp), providing excellent fuel efficiency, strong power density, and long-term durability. At Triton Power, we rely on engines like the Perkins 1104D-E44TAG2 because they ensure reliable power delivery, reduced environmental impact, and the assurance of Perkins’ worldwide parts and service network—making them an exceptional choice for both prime and standby generator sets. The Perkins 1104D-E44TAG2 pairs with a Leroy Somer alternator, and the Deep Sea DSE 7420 digital control panel makes monitoring and management straightforward. The TP-P100-T3-UL is built to rugged specifications and delivers power exactly where and when you need it.
The TP-P100-T3-UL includes the following standard features:
Triton EPA Generators are compliant for emergency stationary use throughout the United States and Canada. Our generators are engineered to operate in the most challenging environments and can be modified to meet virtually any application. With standalone models ranging from 10 kW to 2,500 kW, paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for durable and reliable power generation are essentially unlimited.
Listed in our industry catalogs: Restaurants & hospitality
Values are shown exactly as published. Anything not listed is marked “Not specified”.
Download full specifications| Triton Model | TP-P100-T3-UL |
|---|---|
| Typical Generator Output | Standby: 125 kVA / 100 kW Prime: 113 kVA / 90 kW |
| Engine Brand | Perkins |
|---|---|
| Engine Model | 1104D-E44TAG2 |
| Engine Power Output | 117 kWm / 156.8 HP @ 1800 RPM |
| Aspiration | Turbocharged |
| Displacement | 4.4 L |
| Cylinders | 4, in line |
| Speed | 1800 RPM |
| Alternator Brand | Leroy Somer |
|---|---|
| Alternator Model | LSA44.3S5 |
| Insulation Class | H |
| Frequency | 60 Hz |
|---|---|
| Voltages Available | 120/208, 277/480 |
| Control Panel | Deep Sea DSE 7420 |
|---|
| Models Available | Enclosed, Open Skid |
|---|
| Engine Tier Rating | Tier 3 |
|---|---|
| Compliance | UL 2200 Listed, EPA Tier 3, NFPA 110 compatible |
| Dimensions | Not specified |
|---|---|
| Weight | Not specified |
| Configurations | Enclosed, Open Skid |
Dimensions and weight are not published for this model. Ask for the data sheet.
| Emissions | Tier 3 EPA Certified — Emergency Stationary Applications |
|---|---|
| Market | USA EPA-certified |
| UL 2200 | Listed |
Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.
These parts name this engine model in their own description. Confirm your engine serial number when ordering.
T423548 · Engine part
Perkins
List price $387.28
2654407 · Filter / belt
Perkins
List price $82.15
Our engineers match transfer switches, fuel systems and trailers to this generator's rating when you request a quote.
Same market and frequency, nearest in size. Tick up to three to compare with this model.
TP-NG100-S-K-UL
Engine PSI
TP-P100-T3
Engine Perkins
TP-NG80-S-K-UL
Engine PSI
TP-P80-T3
Engine Perkins
| Model | TP-P100-T3-ULThis model | TP-NG100-S-K-UL | TP-P100-T3 | TP-NG80-S-K-UL | TP-P80-T3 |
|---|---|---|---|---|---|
| Standby | 100 kW / 125 kVA | 100 kW / 125 kVA | 100 kW / 125 kVA | 80 kW / 100 kVA | 80 kW / 100 kVA |
| Prime | 90 kW / 113 kVA | — | 90 kW / 113 kVA | — | 72 kW / 90 kVA |
| Engine | Perkins 1104D-E44TAG2 | PSI Engine 5.7LT CAC | Perkins 1104D-E44TAG2 | PSI Engine 5.7LT | Perkins 1104D-E44TAG1 |
| Alternator | Leroy Somer LSA44.3S5 | — | Leroy Somer LSA44.3S5 | — | Leroy Somer LSA 44.3 S3 |
| Control panel | Deep Sea DSE 7420 | — | DSE7420 | — | DSE7420 |
| Frequency | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
| Voltages | 120/208, 277/480 | — | 120/208, 277/480, 120/240 | — | 120/208, 277/480, 120/240 |
| Configuration | Enclosed, Open Skid | — | Enclosed, Open | — | Enclosed, Open |
| Fuel tank | — | — | — | — | — |
| Market | USA EPA-certified | USA EPA-certified | USA EPA-certified | USA EPA-certified | USA EPA-certified |
Tick “Compare” on a model above to add it to this table.
Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.