60 HzInternational
1000 kW Triton Diesel Generator TP-CK1000-T1-C International Use
TP-CK1000-T1-C
Engine Cummins KTA38-G4
- Standby
- 1,011 kW / 1,264 kVA
- Prime
- 923 kW / 1,153 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
Units marked International are built for markets outside the United States and Canada.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
Units marked International are built for markets outside the United States and Canada. Set where it will be used for frequency and market suggestions, or use the Market filter to see only the units for your destination.
60 HzInternational
TP-CK1000-T1-C
Engine Cummins KTA38-G4
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P1100-T1-50
Engine Perkins 4012-46TWG2A
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-P1100-T1
Engine Perkins 4012-46TWG2A
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-C1250-T1-C-50
Engine Cummins KTA50-G3
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-P1200-T1-60
Engine Perkins 4012-46TWG3A
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-CK1250-T1-C-60
Engine Cummins KTA50-G3
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P1330-T1-50
Engine Perkins 4012-46TAG2A
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-P1330-T1
Engine Perkins 4012-46TAG2A
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C1500-T1-C
Engine Cummins KTA50-G9
Diesel · 60 Hz · Enclosed or open
50 HzInternational
TP-P1500-T1-60
Engine Perkins 4012-46TAG3A
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-P1500-T1-50
Engine Perkins 4012-46TAG3A
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-P1750-T1-50
Engine Perkins 4016TAG1A
Diesel · 50 Hz · Enclosed or open
Not sure which generator you need?
Tell us what you're powering, the destination country, the estimated load and whether it is standby or prime, and our team can help recommend a suitable generator.
50 HzInternational
TP-P1850-T1-50
Engine Perkins 4016-61TRG1
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-P2000-T1-50
Engine Perkins 4016-61TRG2
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-C2000-T1-C-50
Engine Cummins QSK60-G7
Diesel · 50 Hz · Enclosed or open
50 HzInternational
TP-P2250-T1-50
Engine Perkins 4016-61TRG3
Diesel · 50 Hz · Enclosed or open
60 HzInternational
TP-C2000-T1-C-60
Engine Cummins QSK60-G7
Diesel · 60 Hz · Enclosed or open
60 HzInternational
TP-C2500-T1-C-60
Engine Cummins QSK78-G7
Diesel · 60 Hz · Enclosed or open
Showing 18 of 18
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 18 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 18 units here, 10 at 50 Hz and 8 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 18 of the 18 units here are offered in more than one configuration.
Units marked International are built for markets outside the United States and Canada. Each of their product pages carries the published US/Canada restriction.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
Units marked International are built for markets outside the United States and Canada. That label applies to all 18 units listed as 1001 kW and up Export Generators: Triton diesel sets rated from 1011 kW to 2500 kW standby, with Perkins (11) or Cummins (7) engines.
The split is close, with 10 units at 50 Hz and 8 at 60 Hz. Most of Europe, together with large parts of Asia and Africa, uses 50 Hz, while North America mainly uses 60 Hz, and the generator must match both the local grid and the motors and equipment it will run. More 60 Hz export options appear under 60 Hz export generators.
Both enclosed and open versions are listed for all 18. For projects where the set will run as the main supply rather than as backup, ask about the prime rating, which is lower than the standby figures shown. To narrow it down, tell us the destination country and the load.
Tell us your required power, destination and application. Our team can help identify the right generator.