15 kVA Triton Diesel Generator TP-P16-T1-50 International Use

SKU TP-P16-T1-50

Standby rating

17 kVA 13 kW

Prime rating

15 kVA 12 kW

Engine
Perkins 403A-15G2
Alternator
Leroy Somer LSA40S4
Control panel
DSE7420
Fuel
Diesel
Frequency / phase
50 Hz · 3-phase
Voltages listed
110/220 · 240/380
Configuration
Enclosed · Open
Fuel tank
100 L

Market compatibility

International market

Triton International generators are not compliant for use in the United States or Canada due to the emissions status.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.

Markets with a verified 50 Hz grid: Africa (13) · Middle East (5) · Caribbean & Central America (1) · Latin America (3) · Asia-Pacific (7) · Countries A–Z

Overview

Product overview

The TP-P16-T1-50 is a 17 kVA / 13 kW standby, 15 kVA / 12 kW prime diesel generator for international markets.

It uses a Perkins 403A-15G2 engine, a Leroy Somer LSA40S4 alternator and a DSE7420 control panel.

It is listed at 50 Hz, 3-phase, with voltages 110/220 and 240/380, in enclosed or open configurations.

  • Powered by Perkins 403A-15G2
  • Emissions: Not EPA Certified – Export Use Only
  • 50 Hz Power Rating at 3 Phase
  • Standby Power Rating: 17 kVA / 13 kW
  • Prime Power Rating: 15 kVA / 12 kW
  • Fuel Capacity 100 L
Read the full product description

We have diesel and natural gas generators from 10 to 10,000 kW. Our International Triton Generators are built to withstand the harsh environment throughout the Caribbean, South America and Africa. Triton generators power everything including Hotels, Marinas, Factories, Warehousing, Government Buildings to full Island Power. Triton Mobile Generators are utilized for their unsurpassed reliability, efficiency, and quiet performance. Triton is the brand you can rely on when you need dependable power.

Our TP-P16-T1-S-50 provides a standby rating of 13kW / 17kVA and a prime rating of 12kW / 15kVA. The TP-P16-T1-S-50 is built to rugged specifications and provides the power where and when you need it. By utilizing a Perkins 403A-15G2, this generator set will provide you with unsurpassed performance and reliability.

The TP-P16-T1-S-50 includes just a few of the following features:
Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open & Enclosed
Sub-Base Tank 8-10 Hours

Triton International generators are not compliant for use in the United States or Canada due to the emissions status. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.

Why choose this model

  • Perkins 403A-15G2 engineEngine data sheet included below
  • Standby & prime rated17 kVA / 13 kW standby · 15 kVA / 12 kW prime
  • 50 Hz, 3-phaseVoltages listed: 110/220, 240/380
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA40S4 alternatorAlternator specifications included below
  • DSE7420 control panelControl panel listed for this model

Typical applications

  • Hotels
  • Marinas
  • Factories
  • Warehousing
  • Government Buildings
  • Island Power

As named in the Triton product description.

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-P16-T1-50
kVA / kW Standby 17 kVA / 13 kW
kVA / kW Prime 15 kVA / 12 kW
Engine
Engine Brand Perkins
Engine Model 403A-15G2
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA40S4
Electrical
Voltages Available 110/220, 240/380
Fuel System
Fuel Tank Capacity 100 L
Control
Control Panel DSE7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsNot EPA Certified – Export Use Only
MarketInternational market
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Compatible with this engine

Parts listed for 403A-15G2

These parts name this engine model in their own description. Confirm your engine serial number when ordering.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-P16-T1-50 with similar models
ModelTP-P16-T1-50This model TP-P22-T1-50TP-P10-T1-50TP-P33-T1-50TP-P50-T1-50
Standby17 kVA / 13 kW22.1 kVA / 17.7 kW10 kVA / 8 kW33 kVA / 26 kW49 kVA / 39 kW
Prime15 kVA / 12 kW20 kVA / 16 kW9 kVA / 7.2 kW30 kVA / 24 kW45 kVA / 36 kW
EnginePerkins 403A-15G2Perkins 404D-22GPerkins 403D-11GPerkins 1103A-33GPerkins 1103A-33TG1
AlternatorLeroy Somer LSA40S4Leroy Somer LSA40M5Leroy Somer LSA40VS1Leroy Somer LSA42.3VS3Leroy Somer LSA42.3M7
Control panelDSE7420DSE7420DSE7420DSE7420DSE7420
Frequency50 Hz50 Hz50 Hz50 Hz50 Hz
Voltages110/220, 240/380110/220, 240/380110/220, 240/380110/220, 240/380110/220, 240/380
ConfigurationEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, Open
Fuel tank100 L130 L8-10 Hours160 L320 L
MarketInternational marketInternational marketInternational marketInternational marketInternational market
International export support

Buying this generator for an international project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

Supported by Global Generator Supply

+1 251-314-4812

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request