150 kW Triton Diesel Generator TP-P150-T3 EPA Certified
TP-P150-T3
- Standby
- 153 kW / 191 kVA
- Prime
- 136 kW / 170 kVA
Engine Perkins
Commercial & Industrial Power Equipment Worldwide
SKU TP-P150-T3-UL
Market compatibility
USA EPA-certified
Tier 3 EPA Certified — Emergency Stationary Applications · Tier 3 – UL Listed
Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.
The TP-P150-T3-UL is a 191 kVA / 153 kW standby, 170 kVA / 136 kW prime diesel generator, EPA-certified for the US market.
It uses a Perkins 1106D-E70TAG3 engine, a Leroy Somer LSA44.3L12 alternator and a Deep Sea DSE 7420 control panel.
It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480, in enclosed or open skid configurations.
EPA Tier 3 Certified for Emergency Stationary use in the US and Canada.
Triton EPA Generators are compliant for emergency stationary use throughout the United States and Canada.
As named in the manufacturer's description of this model.
Listed in our industry catalogs: Data centers, Restaurants & hospitality
Values are shown exactly as published. Anything not listed is marked “Not specified”.
Download full specifications| Triton Model | TP-P150-T3-UL |
|---|---|
| Typical Generator Output | Standby: 191 kVA / 153 kW Prime: 170 kVA / 136 kW |
| Engine Brand | Perkins |
|---|---|
| Engine Model | 1106D-E70TAG3 |
| Engine Power Output | 178 kWm / 239 HP @ 1800 RPM |
| Aspiration | Turbocharged Aftercooled |
| Displacement | 7.01 L |
| Cylinders | 6, in line |
| Speed | 1800 RPM |
| Alternator Brand | Leroy Somer |
|---|---|
| Alternator Model | LSA44.3L12 |
| Insulation Class | H |
| Frequency | 60 Hz |
|---|---|
| Voltages Available | 120/208, 277/480 |
| Control Panel | Deep Sea DSE 7420 |
|---|
| Models Available | Enclosed, Open Skid |
|---|
| Engine Tier Rating | Tier 3 |
|---|---|
| Compliance | UL 2200 Listed, EPA Tier 3, NFPA 110 compatible |
| Dimensions | Not specified |
|---|---|
| Weight | Not specified |
| Configurations | Enclosed, Open Skid |
Dimensions and weight are not published for this model. Ask for the data sheet.
| Emissions | Tier 3 EPA Certified — Emergency Stationary Applications |
|---|---|
| Market | USA EPA-certified |
| UL 2200 | Listed |
Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.
Our engineers match transfer switches, fuel systems and trailers to this generator's rating when you request a quote.
Same market and frequency, nearest in size. Tick up to three to compare with this model.
TP-P150-T3
Engine Perkins
TP-P175-T3
Engine Perkins
TP-P200-T3-UL
Engine Perkins
TP-C200-T3
Engine Cummins
| Model | TP-P150-T3-ULThis model | TP-P150-T3 | TP-P175-T3 | TP-P200-T3-UL | TP-C200-T3 |
|---|---|---|---|---|---|
| Standby | 153 kW / 191 kVA | 153 kW / 191 kVA | 175 kW / 219 kVA | 200 kW / 250 kVA | 200 kW / 250 kVA |
| Prime | 136 kW / 170 kVA | 136 kW / 170 kVA | 160 kW / 200 kVA | 180 kW / 225 kVA | 180 kW / 225 kVA |
| Engine | Perkins 1106D-E70TAG3 | Perkins 1106D-E70TAG3 | Perkins 1106D-E70TAG4 | Perkins 1106D-E70TAG5 | Cummins QSB7-G5 |
| Alternator | Leroy Somer LSA44.3L12 | Leroy Somer LSA 44.3 L12 | Leroy Somer LSA 44.3 VL13 | Leroy Somer LSA46.3S4 | — |
| Control panel | Deep Sea DSE 7420 | DSE7420 | DSE7420 | Deep Sea DSE 7420 | Deep Sea |
| Frequency | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
| Voltages | 120/208, 277/480 | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 | 120/208, 277/480 | 120/208, 277/480 |
| Configuration | Enclosed, Open Skid | Enclosed, Open | Enclosed, Open | Enclosed, Open Skid | Enclosed, Open |
| Fuel tank | — | — | — | — | — |
| Market | USA EPA-certified | USA EPA-certified | USA EPA-certified | USA EPA-certified | USA EPA-certified |
Tick “Compare” on a model above to add it to this table.
Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.