150 kW Triton Diesel Generator TP-P150-T3 EPA Certified
TP-P150-T3
- Standby
- 153 kW / 191 kVA
- Prime
- 136 kW / 170 kVA
Engine Perkins
Commercial & Industrial Power Equipment Worldwide
SKU TP-P175-T3
Market compatibility
USA EPA-certified
Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.
Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.
The TP-P175-T3 is a 219 kVA / 175 kW standby, 200 kVA / 160 kW prime diesel generator, EPA-certified for the US market.
It uses a Perkins 1106D-E70TAG4 engine, a Leroy Somer LSA 44.3 VL13 alternator and a DSE7420 control panel.
It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.
Global Generator Supply provides Emergency Stationary generators that are certified to Tier 4i, 3 and 2 depending upon the generator rating required. We provide UL2200, CSA and other certifications. Triton can build nearly any type of generator for your requirements, including both gaseous and diesel generators. Further, we maintain a stock of generators built to standard specifications for immediate shipment, including trailers, transfer switches and fuel tanks.
Triton EPA Generators are to exacting standards for the US and Canadian markets. We provide options for everything from hurricane zones to the harsh environment of the far north. Triton Generators are used at a variety of locations including government facilities, hotels, factories, medical facilities and grocery stores.
Our TP-P175-T3 provides a standby rating of 175kW / 219kVA and a prime rating of 160kW / 200kVA. The TP-P175-T3 is built to rugged specifications and provides the power where and when you need it. By utilizing a Perkins engine model 1106D-E70TAG4, this generator set will provide you with the EPA standards and also provide unsurpassed performance and reliability.
The TP-P175-T3 includes just a few of the following features:
Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open and Enclosed
8 to 10 Hours Fuel Tank
Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.
Listed in our industry catalogs: Data centers, Restaurants & hospitality
Values are shown exactly as published. Anything not listed is marked “Not specified”.
Download full specifications| Triton Model | TP-P175-T3 |
|---|---|
| kVA / kW Standby | 219 kVA / 175 kW |
| kVA / kW Prime | 200 kVA / 160 kW |
| Engine Brand | Perkins |
|---|---|
| Engine Model | 1106D-E70TAG4 |
| Alternator Brand | Leroy Somer |
|---|---|
| Alternator Model | LSA 44.3 VL13 |
| Voltages Available | 120/208, 277/480, 120/240 |
|---|
| Fuel Tank Capacity | n/a |
|---|
| Control Panel | DSE7420 |
|---|
| Models Available | Enclosed, Open |
|---|
| Dimensions | Not specified |
|---|---|
| Weight | Not specified |
| Configurations | Enclosed, Open |
Dimensions and weight are not published for this model. Ask for the data sheet.
| Emissions | Tier 3 EPA Certified Emergency Stationary Applications |
|---|---|
| Market | USA EPA-certified |
Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.
Our engineers match transfer switches, fuel systems and trailers to this generator's rating when you request a quote.
Same market and frequency, nearest in size. Tick up to three to compare with this model.
TP-P150-T3
Engine Perkins
TP-P150-T3-UL
Engine Perkins
TP-P200-T3-UL
Engine Perkins
TP-C200-T3
Engine Cummins
| Model | TP-P175-T3This model | TP-P150-T3 | TP-P150-T3-UL | TP-P200-T3-UL | TP-C200-T3 |
|---|---|---|---|---|---|
| Standby | 175 kW / 219 kVA | 153 kW / 191 kVA | 153 kW / 191 kVA | 200 kW / 250 kVA | 200 kW / 250 kVA |
| Prime | 160 kW / 200 kVA | 136 kW / 170 kVA | 136 kW / 170 kVA | 180 kW / 225 kVA | 180 kW / 225 kVA |
| Engine | Perkins 1106D-E70TAG4 | Perkins 1106D-E70TAG3 | Perkins 1106D-E70TAG3 | Perkins 1106D-E70TAG5 | Cummins QSB7-G5 |
| Alternator | Leroy Somer LSA 44.3 VL13 | Leroy Somer LSA 44.3 L12 | Leroy Somer LSA44.3L12 | Leroy Somer LSA46.3S4 | — |
| Control panel | DSE7420 | DSE7420 | Deep Sea DSE 7420 | Deep Sea DSE 7420 | Deep Sea |
| Frequency | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
| Voltages | 120/208, 277/480, 120/240 | 120/208, 277/480, 120/240 | 120/208, 277/480 | 120/208, 277/480 | 120/208, 277/480 |
| Configuration | Enclosed, Open | Enclosed, Open | Enclosed, Open Skid | Enclosed, Open Skid | Enclosed, Open |
| Fuel tank | — | — | — | — | — |
| Market | USA EPA-certified | USA EPA-certified | USA EPA-certified | USA EPA-certified | USA EPA-certified |
Tick “Compare” on a model above to add it to this table.
Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.