Commercial & Industrial Power Equipment Worldwide

Equipment for use in
200 kW Triton Diesel Generator TP-C200-T3 EPA Certified
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 3 technical documentsspec sheet, engine data, brochure
60 Hz USA EPA Tier 3

200 kW Triton Diesel Generator TP-C200-T3 EPA Certified

SKU TP-C200-T3

Standby rating

200 kW 250 kVA

Prime rating

180 kW 225 kVA

Engine
Cummins QSB7-G5
Alternator
Not specified
Control panel
Deep Sea
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480
Configuration
Enclosed · Open
Fuel tank
Not specified

Market compatibility

USA EPA-certified

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.

Specifications being verified

Our engineering team is confirming some details on this page (standby kw). Please confirm model and ratings with sales before ordering.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-C200-T3 is a 250 kVA / 200 kW standby, 225 kVA / 180 kW prime diesel generator, EPA-certified for the US market.

It uses a Cummins QSB7-G5 engine and a Deep Sea control panel.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480, in enclosed or open configurations.

  • Engine: Cummins QSB7-G5
  • Emissions: Tier 3 EPA Certified Emergency Stationary Applications
  • 60 Hz, three-phase
  • Standby: 200 kW / 250 kVA
  • Prime: 180 kW / 225 kVA

Why choose this model

  • Cummins QSB7-G5 engineEngine data sheet included below
  • Standby & prime rated200 kW / 250 kVA standby · 180 kW / 225 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480
  • Enclosed or OpenConfigurations available for this model
  • Deep Sea control panelControl panel listed for this model

Typical applications

  • government facilities
  • hotels
  • factories
  • medical facilities
  • grocery stores

As named in the manufacturer's description of this model.

Listed in our industry catalogs: Data centers, Manufacturing, Oil & gas, Restaurants & hospitality

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-C200-T3
kVA / kW Standby 250 kVA / 200 kW
kVA / kW Prime 225 kVA / 180 kW
Engine
Engine Brand Cummins
Engine Model QSB7-G5
Alternator
Alternator Brand –
Alternator Model –
Electrical
Voltages Available 120/208, 277/480
Fuel System
Fuel Tank Capacity n/a
Control
Control Panel Deep Sea
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 3 EPA Certified Emergency Stationary Applications
MarketUSA EPA-certified
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-C200-T3 with similar models
ModelTP-C200-T3This model TP-P200-T3-ULTP-P175-T3TP-P150-T3TP-P150-T3-UL
Standby200 kW / 250 kVA200 kW / 250 kVA175 kW / 219 kVA153 kW / 191 kVA153 kW / 191 kVA
Prime180 kW / 225 kVA180 kW / 225 kVA160 kW / 200 kVA136 kW / 170 kVA136 kW / 170 kVA
EngineCummins QSB7-G5Perkins 1106D-E70TAG5Perkins 1106D-E70TAG4Perkins 1106D-E70TAG3Perkins 1106D-E70TAG3
Alternator—Leroy Somer LSA46.3S4Leroy Somer LSA 44.3 VL13Leroy Somer LSA 44.3 L12Leroy Somer LSA44.3L12
Control panelDeep SeaDeep Sea DSE 7420DSE7420DSE7420Deep Sea DSE 7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480120/208, 277/480120/208, 277/480, 120/240120/208, 277/480, 120/240120/208, 277/480
ConfigurationEnclosed, OpenEnclosed, Open SkidEnclosed, OpenEnclosed, OpenEnclosed, Open Skid
Fuel tank—————
MarketUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certified
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request