220 kVA Triton Diesel Generator TP-P220-T1-50 International Use
TP-P220-T1
- Standby
- 220 kW / 275 kVA
- Prime
- 200 kW / 250 kVA
Engine Perkins
Commercial & Industrial Power Equipment Worldwide
SKU TP-P220-T1-50 Model TP-P200-T1-50
Market compatibility
International market
Triton International generators are not compliant for use in the United States or Canada due to the emissions status.
Our engineering team is confirming some details on this page (model, standby kva). Please confirm model and ratings with sales before ordering.
Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.
Markets with a verified 50 Hz grid: Africa (13) · Middle East (5) · Caribbean & Central America (1) · Latin America (3) · Asia-Pacific (7) · Countries A–Z
The TP-P220-T1-50 is a 250 kVA / 200 kW standby, 225 kVA / 180 kW prime diesel generator for international markets.
It uses a Perkins 1206A-E70TTAG2 engine, a Leroy Somer LSA46.3S4 alternator and a DSE7420 control panel.
It is listed at 50 Hz, 3-phase, with voltages 110/220 and 240/380, in enclosed or open configurations.
We have diesel and natural gas generators from 10 to 10,000 kW. Our International Triton Generators are built to withstand the harsh environment throughout the Caribbean, South America and Africa. Triton generators power everything including Hotels, Marinas, Factories, Warehousing, Government Buildings to full Island Power. Triton Mobile Generators are utilized for their unsurpassed reliability, efficiency, and quiet performance. Triton is the brand you can rely on when you need dependable power.
Our TP-P200-T1-50 provides a standby rating of 200kW / 250kVA and a prime rating of 180kW / 225kVA. The TP-P200-T1-50 is built to rugged specifications and provides the power where and when you need it. By utilizing a Perkins 1206A-E70TTAG2, this generator set will provide you with unsurpassed performance and reliability.
The TP-P200-T1-50 includes just a few of the following features:
Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open & Enclosed
Sub-Base Tank 8-10 Hours
Triton International generators are not compliant for use in the United States or Canada due to the emissions status. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.
As named in the Triton product description.
Values are shown exactly as published. Anything not listed is marked “Not specified”.
Download full specifications| Triton Model | TP-P200-T1-50 |
|---|---|
| kVA / kW Standby | 250 kVA / 200 kW |
| kVA / kW Prime | 225 kVA / 180 kW |
| Engine Brand | Perkins |
|---|---|
| Engine Model | 1206A-E70TTAG2 |
| Alternator Brand | Leroy Somer |
|---|---|
| Alternator Model | LSA46.3S4 |
| Voltages Available | 110/220, 240/380 |
|---|
| Fuel Tank Capacity | 380 L |
|---|
| Control Panel | DSE7420 |
|---|
| Models Available | Enclosed, Open |
|---|
| Dimensions | Not specified |
|---|---|
| Weight | Not specified |
| Configurations | Enclosed, Open |
Dimensions and weight are not published for this model. Ask for the data sheet.
| Emissions | Not EPA Certified – Export Use Only |
|---|---|
| Market | International market |
Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.
Our engineers match transfer switches, fuel systems and trailers to this generator's rating when you request a quote.
Same market and frequency, nearest in size. Tick up to three to compare with this model.
TP-P220-T1
Engine Perkins
TP-P200-T1-50
Engine Perkins
TP-P310-T1-60
Engine Perkins
TP-P165-T1-50
Engine Perkins
| Model | TP-P220-T1-50This model | TP-P220-T1 | TP-P200-T1-50 | TP-P310-T1-60 | TP-P165-T1-50 |
|---|---|---|---|---|---|
| Standby | 250 kVA / 200 kW | 275 kVA / 220 kW | 198 kVA / 158 kW | 335 kVA / 267 kW | 165 kVA / 132 kW |
| Prime | 225 kVA / 180 kW | 250 kVA / 200 kW | 180 kVA / 144 kW | 300 kVA / 240 kW | 150 kVA / 120 kW |
| Engine | Perkins 1206A-E70TTAG2 | Perkins 1206A-E70TTAG3 | Perkins 1106A-70TAG3 | Perkins 1506A-E88TAG5 | Perkins 1106A-70TAG2 |
| Alternator | Leroy Somer LSA46.3S4 | Leroy Somer LSA46.3S4 | Leroy Somer LSA44.3VL13 | Leroy somer LSA46.3L10 | Leroy Somer LSA44.3VL14 |
| Control panel | DSE7420 | DSE | DSE7420 | DSE7420 | DSE7420 |
| Frequency | 50 Hz | 50 Hz | 50 Hz | 50 Hz | 50 Hz |
| Voltages | 110/220, 240/380 | 220/380 | 110/220, 240/380 | 110/220, 240/380 | 110/220, 240/380 |
| Configuration | Enclosed, Open | Enclosed, Open | Enclosed, Open | Enclosed, Open | Enclosed, Open |
| Fuel tank | 380 L | 420 L | 8-10 Hr | — | 8-10 Hr |
| Market | International market | International market | International market | International market | International market |
Tick “Compare” on a model above to add it to this table.