60 HzTier 4 FinalMobile
350 kVA Triton Rental Grade Generator TP-RS350-T4F-RENTAL Tier 4 Rental
TP-RS350-T4F-RENTAL
Engine Scania DC13 084A
- Standby
- 308 kW / 385 kVA
- Prime
- 280 kW / 350 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
The 12 mobile generators in this 301-500 kW class are all diesel and all produce 60 Hz, the frequency North America mainly uses. Standby ratings range from 308 kW to 500 kW, and each set is listed in both an enclosed and an open version.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzTier 4 FinalMobile
TP-RS350-T4F-RENTAL
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S350-T4F
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS400-T4F-RENTAL
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C350-T3-SAE
Engine Cummins QSZ13-G6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C400-T3-SAE
Engine Cummins QSZ13-G7
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S440-T4F
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS500-T4F-RENTAL
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD440-T4F
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD500-T4F
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD500-T4F-RENTAL
Engine John Deere 6136CG550
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C450-T3
Engine Cummins QSX15-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C500-T3
Engine Cummins QSX15-G9
Diesel · 60 Hz · Enclosed or open
Showing 12 of 12
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 12 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 12 units here, 12 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 12 of the 12 units here are offered in more than one configuration. 12 are mobile units.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
The 12 mobile generators in this 301-500 kW class are all diesel and all produce 60 Hz, the frequency North America mainly uses. Standby ratings range from 308 kW to 500 kW, and each set is listed in both an enclosed and an open version.
A mobile set often moves from job to job, so review each new site first: the frequency its equipment needs, the size of the load, and whether the set will cover outages or run as the main supply, which calls for its lower prime rating. When you have those details, tell us the destination country and the load. For other sizes, see mobile generators.
Tell us your required power, destination and application. Our team can help identify the right generator.