501-1000 kW Mobile Generators

These 501-1000 kW mobile generators are 9 diesel sets with standby ratings between 550 kW and 898 kW, all producing 60 Hz. Volvo and Scania engines account for 4 units each, and Doosan for 1.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Market
Engine

9 of 9 generators

Generators

Buyer's guide

Choosing a 501–1000 kW generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 9 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 9 units here, 9 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 9 of the 9 units here are offered in more than one configuration. 9 are mobile units.

USA EPA, Tier 4 Final or international?
  • Tier 4 Final (8 here): Tier 4 Final emissions configuration.

About 501-1000 kW Mobile Generators

These 501-1000 kW mobile generators are 9 diesel sets with standby ratings between 550 kW and 898 kW, all producing 60 Hz. Volvo and Scania engines account for 4 units each, and Doosan for 1.

On the market side, 8 units are labeled Tier 4 Final, and for 1 unit eligibility is still being confirmed, so check that listing closely before planning around it.

Every set lists both open and enclosed configurations. A mobile unit working in the open usually calls for an enclosure, which shields it from weather and dampens sound, while an open set fits a room or shelter that already provides cover. Because the ratings shown are standby figures, judge a set that will run as the main supply for long periods on its lower prime rating. Our team can help confirm the right unit if you tell us the destination country and the load.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.