60 HzTier 4 FinalMobile
550 kW Triton Diesel Generator TP-V550-T4F Tier 4 Final
TP-V550-T4F
Engine Volvo TWD1672GE
- Standby
- 550 kW / 688 kVA
- Prime
- 500 kW / 625 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
These 501-1000 kW mobile generators are 9 diesel sets with standby ratings between 550 kW and 898 kW, all producing 60 Hz. Volvo and Scania engines account for 4 units each, and Doosan for 1.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzTier 4 FinalMobile
TP-V550-T4F
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV625-T4F-RENTAL
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS700-T4F-Twin Pack
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V625-T4F
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV713-T4F-RENTAL
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S700-T4F-Twin Pack
Engine Scania DC13 085A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S880-T4F-Twin Pack
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RS1000-T4F-Twin Pack
Engine Scania DC16 084A
Diesel · 60 Hz · Enclosed or open
60 HzConfirmingMobile
TP-D900-T2-60
Engine Doosan DP222CC
Diesel · 60 Hz · Enclosed or open
Market eligibility being confirmed
Showing 9 of 9
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 9 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 9 units here, 9 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 9 of the 9 units here are offered in more than one configuration. 9 are mobile units.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
These 501-1000 kW mobile generators are 9 diesel sets with standby ratings between 550 kW and 898 kW, all producing 60 Hz. Volvo and Scania engines account for 4 units each, and Doosan for 1.
On the market side, 8 units are labeled Tier 4 Final, and for 1 unit eligibility is still being confirmed, so check that listing closely before planning around it.
Every set lists both open and enclosed configurations. A mobile unit working in the open usually calls for an enclosure, which shields it from weather and dampens sound, while an open set fits a room or shelter that already provides cover. Because the ratings shown are standby figures, judge a set that will run as the main supply for long periods on its lower prime rating. Our team can help confirm the right unit if you tell us the destination country and the load.
Tell us your required power, destination and application. Our team can help identify the right generator.