- Export supportconfiguration and shipping quotes for your destination
- Engineering supporthelp with sizing, voltage and configuration
- 6 technical documentsspec sheet, engine data, alternator data, brochure
350 kW Triton Diesel Generator TP-P350-T3-UL Tier 3 – UL Listed
SKU TP-P350-T3-UL
- Engine
- Perkins 2206D-E13TAG2
- Alternator
- Leroy Somer LSA46.3L10
- Control panel
- Deep Sea DSE 7420
- Fuel
- Diesel
- Frequency / phase
- 60 Hz · 3-phase
- Voltages listed
- 120/208 · 277/480
- Configuration
- Enclosed · Open Skid
- Fuel tank
- Not specified
Market compatibility
USA EPA-certified
Tier 3 EPA Certified — Emergency Stationary Applications · Tier 3 – UL Listed
Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.
Product overview
The TP-P350-T3-UL is a 438 kVA / 350 kW standby, 400 kVA / 320 kW prime diesel generator, EPA-certified for the US market.
It uses a Perkins 2206D-E13TAG2 engine, a Leroy Somer LSA46.3L10 alternator and a Deep Sea DSE 7420 control panel.
It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480, in enclosed or open skid configurations.
- Powered by Perkins 2206D-E13TAG2
- Emissions: Tier 3 EPA Certified — Emergency Stationary Applications
- 60 Hz Power Rating, 3-Phase
- Standby Power Rating: 438 kVA / 350 kW
- Prime Power Rating: 400 kVA / 320 kW
- Leroy Somer Alternator
- Deep Sea DSE 7420 Control Panel
- UL2200 Listed
Read the full product description
Global Generator Supply provides Emergency Stationary generators certified to Tier 4i, Tier 3, and Tier 2 ratings, with UL2200, CSA, and other compliance options. Triton can build virtually any generator to spec — gaseous or diesel — and we maintain ready stock of generators built to standard configurations for immediate shipment, along with trailers, transfer switches, and fuel tanks.
Triton EPA Generators are engineered to exacting standards for the US and Canadian markets. We offer options for everything from hurricane zones along the Gulf coast to the harsh climate of the far north. Triton generators are deployed at government facilities, hotels, manufacturing plants, medical facilities, grocery stores, and data centers across North America.
The TP-P350-T3-UL delivers a standby rating of 350 kW / 438 kVA and a prime rating of 320 kW / 400 kVA. The Perkins 2206D-E13TAG2 is a heavy-duty diesel engine built for generator applications that demand dependable power, strong performance, and long-term durability. Designed for both prime and standby use, this engine delivers the reliability needed for industrial, commercial, and mission-critical environments. With its solid construction and consistent power output, it is a practical choice for operators looking for a proven engine platform for demanding power generation needs. The Perkins 2206D-E13TAG2 pairs with a Leroy Somer alternator, and the Deep Sea DSE 7420 digital control panel makes monitoring and management straightforward. The TP-P350-T3-UL is built to rugged specifications and delivers power exactly where and when you need it.
Standard Features
The TP-P350-T3-UL includes the following standard features:
- Perkins 2206D-E13TAG2 Tier 3 diesel engine
- Leroy Somer alternator with Class H insulation
- Deep Sea DSE 7420 programmable digital control panel
- Sound-attenuated steel enclosure, powder-coated finish
- Heavy-duty steel base frame with anti-vibration mounts
- Easy interface and serviceability access on both sides
- Heavy-duty chassis designed to handle any terrain or location
- Available in Open Skid and Enclosed configurations
- UL 2200 Listed
- EPA Tier 3 Certified for Emergency Stationary use in the US and Canada
- Fuel tanks available as an option — contact us for a quote
Why Triton
Triton EPA Generators are compliant for emergency stationary use throughout the United States and Canada. Our generators are engineered to operate in the most challenging environments and can be modified to meet virtually any application. With standalone models ranging from 10 kW to 2,500 kW, paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for durable and reliable power generation are essentially unlimited.
Why choose this model
- Perkins 2206D-E13TAG2 engineEngine data sheet included below
- Standby & prime rated350 kW / 438 kVA standby · 320 kW / 400 kVA prime
- 60 Hz, 3-phaseVoltages listed: 120/208, 277/480
- Enclosed or Open SkidConfigurations available for this model
- Leroy Somer LSA46.3L10 alternatorAlternator specifications included below
- Deep Sea DSE 7420 control panelControl panel listed for this model
Typical applications
Listed in our industry catalogs: Data centers, Healthcare, Manufacturing, Oil & gas, Restaurants & hospitality
Specifications
Values are shown exactly as published. Anything not listed is marked “Not specified”.
Download full specifications| Triton Model | TP-P350-T3-UL |
|---|---|
| Typical Generator Output | Standby: 438 kVA / 350 kW Prime: 400 kVA / 320 kW |
| Engine Brand | Perkins |
|---|---|
| Engine Model | 2206D-E13TAG2 |
| Engine Power Output | 373 kWm / 500 HP @ 1800 RPM |
| Aspiration | Turbocharged Aftercooled |
| Displacement | 12.5 L |
| Cylinders | 6, in line |
| Speed | 1800 RPM |
| Alternator Brand | Leroy Somer |
|---|---|
| Alternator Model | LSA46.3L10 |
| Insulation Class | H |
| Frequency | 60 Hz |
|---|---|
| Voltages Available | 120/208, 277/480 |
| Control Panel | Deep Sea DSE 7420 |
|---|
| Models Available | Enclosed, Open Skid |
|---|
| Engine Tier Rating | Tier 3 |
|---|---|
| Compliance | UL 2200 Listed, EPA Tier 3, NFPA 110 compatible |
| Dimensions | Not specified |
|---|---|
| Weight | Not specified |
| Configurations | Enclosed, Open Skid |
Dimensions and weight are not published for this model. Ask for the data sheet.
| Emissions | Tier 3 EPA Certified — Emergency Stationary Applications |
|---|---|
| Market | USA EPA-certified |
| UL 2200 | Listed |
Technical documents
Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.
- Generator Set Specifications v1 Generator set specificationsDownload
- Generator Set Specifications v2 Generator set specificationsDownload
- Engine Data Sheet Engine data sheetDownload
- Alternator Specifications Alternator specificationsDownload
- Controller Data Sheet Controller data sheetDownload
- Product Brochure Product brochureDownload
Parts listed for 2206D-E13TAG2
These parts name this engine model in their own description. Confirm your engine serial number when ordering.
Secondary Fuel Filter – Perkins Engine Model 2206D-E13TAG2
CH10931 · Filter / belt
Perkins
List price $117.65
Everything this unit needs on site
Our engineers match transfer switches, fuel systems and trailers to this generator's rating when you request a quote.
- Automatic transfer switchAutomatic transfer switches from 100 to 4,000 A. Matched to this unit on request View transfer switches
- Fuel system16 double wall and 19 single wall tanks, UL 142 and non-UL. Matched to this unit on request View fuel tanks
- TrailerOpen-deck and generator trailers. Matched to this unit on request View trailers
- Parts for the 2206D-E13TAG23 parts name this engine model in their own description. Compatible with this engine See compatible parts
Compare with similar models
Same market and frequency, nearest in size. Tick up to three to compare with this model.
- 60 Hz USA EPA
350 kW Triton Diesel Generator TP-P350-T3 EPA Certified
TP-P350-T3
- Standby
- 350 kW / 438 kVA
- Prime
- 320 kW / 400 kVA
Engine Perkins
- 60 Hz USA EPA Mobile
350 kW Triton Diesel Generator TP-C350-T3-SAE EPA Certified
TP-C350-T3-SAE
- Standby
- 359 kW / 448 kVA
- Prime
- 315 kW / 394 kVA
Engine Cummins
- 60 Hz USA EPA UL2200
300 kW Triton Diesel Generator TP-P300-T3-UL Tier 3 – UL Listed
TP-P300-T3-UL
- Standby
- 308 kW / 385 kVA
- Prime
- 280 kW / 350 kVA
Engine Perkins
- 60 Hz USA EPA
400 kW Triton Diesel Generator TP-P400-T3 EPA Certified
TP-P400-T3
- Standby
- 400 kW / 500 kVA
- Prime
- 360 kW / 450 kVA
Engine Perkins
| Model | TP-P350-T3-ULThis model | TP-P350-T3 | TP-C350-T3-SAE | TP-P300-T3-UL | TP-P400-T3 |
|---|---|---|---|---|---|
| Standby | 350 kW / 438 kVA | 350 kW / 438 kVA | 359 kW / 448 kVA | 308 kW / 385 kVA | 400 kW / 500 kVA |
| Prime | 320 kW / 400 kVA | 320 kW / 400 kVA | 315 kW / 394 kVA | 280 kW / 350 kVA | 360 kW / 450 kVA |
| Engine | Perkins 2206D-E13TAG2 | Perkins 2206D-E13TAG2 | Cummins QSZ13-G6 | Perkins 1706D-E93TAG2 | Perkins 2206D-E13TAG3 |
| Alternator | Leroy Somer LSA46.3L10 | Leory Somer LSA46.3L11 | — | Leroy Somer LSA46.3L11 | Leroy Somer LSA47.2VS2 |
| Control panel | Deep Sea DSE 7420 | DSE7420 | — | Deep Sea DSE 7420 | DSE7420 |
| Frequency | 60 Hz | 60 Hz | 60 Hz | 60 Hz | 60 Hz |
| Voltages | 120/208, 277/480 | 120/208, 277/480, 120/240 | 120/208, 277/480 | 120/208, 277/480 | 120/208, 277/480, 120/240 |
| Configuration | Enclosed, Open Skid | Enclosed, Open | Enclosed, Open | Enclosed, Open Skid | Enclosed, Open |
| Fuel tank | — | — | — | — | — |
| Market | USA EPA-certified | USA EPA-certified | USA EPA-certified | USA EPA-certified | USA EPA-certified |
Tick “Compare” on a model above to add it to this table.
Buying this generator for a project?
Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.
Supported by Global Generator Supply
- Engineeringhelp with sizing, voltage and configuration
- Export supportdocuments and shipping quotes on request
- Partsparts and components for your equipment
- Quote listcombine several products in one request