Commercial & Industrial Power Equipment Worldwide

Equipment for use in
400 kW Triton Diesel Generator TP-P400-T3 EPA Certified
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 4 technical documentsspec sheet, engine data, alternator data, brochure
60 Hz USA EPA Tier 3

400 kW Triton Diesel Generator TP-P400-T3 EPA Certified

SKU TP-P400-T3

Standby rating

400 kW 500 kVA

Prime rating

360 kW 450 kVA

Engine
Perkins 2206D-E13TAG3
Alternator
Leroy Somer LSA47.2VS2
Control panel
DSE7420
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480 · 120/240
Configuration
Enclosed · Open
Fuel tank
Not specified

Market compatibility

USA EPA-certified

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-P400-T3 is a 500 kVA / 400 kW standby, 450 kVA / 360 kW prime diesel generator, EPA-certified for the US market.

It uses a Perkins 2206D-E13TAG3 engine, a Leroy Somer LSA47.2VS2 alternator and a DSE7420 control panel.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480 and 120/240, in enclosed or open configurations.

  • Powered by Perkins 2206D-E13TAG3
  • Emissions: Tier 3 EPA Certified Emergency Stationary Applications
  • 60 Hz Power Rating at 3 Phase
  • Standby Power Rating: 500 kVA / 400 kW
  • Prime Power Rating: 450 kVA / 360 kW
Read the full product description

Global Generator Supply provides Emergency Stationary generators that are certified to Tier 4i, 3 and 2 depending upon the generator rating required. We provide UL2200, CSA and other certifications. Triton can build nearly any type of generator for your requirements, including both gaseous and diesel generators. Further, we maintain a stock of generators built to standard specifications for immediate shipment, including trailers, transfer switches and fuel tanks.

Triton EPA Generators are to exacting standards for the US and Canadian markets. We provide options for everything from hurricane zones to the harsh environment of the far north. Triton Generators are used at a variety of locations including government facilities, hotels, factories, medical facilities and grocery stores.

Our TP-P400-T3 provides a standby rating of 400kW / 500kVA and a prime rating of 360kW / 450kVA. The TP-P400-T3 is built to rugged specifications and provides the power where and when you need it. By utilizing a Perkins engine model 2206D-E13TAG3, this generator set will provide you with the EPA standards and also provide unsurpassed performance and reliability.

The TP-P400-T3 includes just a few of the following features:

Programmable Control Panel
Easy Interface and Serviceability Access
Quiet Operation (as low as 64 dBA)
Heavy-Duty Chassis designed to handle any terrain or location
Available in Open and Enclosed
8 to 10 Hours Fuel Tank

Triton EPA Generators are compliant for use in the United States or Canada for emergency stationary applications. Our generators are engineered to operate in the most challenging environments and can be modified to meet any application. With standalone models ranging from 10 kW to 2500 kW and paralleled generators up to 20 MW, and the ability to customize a unit to fit any need, your options for a durable and reliable power generation solution are endless.

Why choose this model

  • Perkins 2206D-E13TAG3 engineEngine data sheet included below
  • Standby & prime rated400 kW / 500 kVA standby · 360 kW / 450 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480, 120/240
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA47.2VS2 alternatorAlternator specifications included below
  • DSE7420 control panelControl panel listed for this model

Typical applications

Listed in our industry catalogs: Data centers, Healthcare, Manufacturing, Oil & gas, Restaurants & hospitality

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-P400-T3
kVA / kW Standby 500 kVA / 400 kW
kVA / kW Prime 450 kVA / 360 kW
Engine
Engine Brand Perkins
Engine Model 2206D-E13TAG3
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA47.2VS2
Electrical
Voltages Available 120/208, 277/480, 120/240
Fuel System
Fuel Tank Capacity n/a
Control
Control Panel DSE7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 3 EPA Certified Emergency Stationary Applications
MarketUSA EPA-certified
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-P400-T3 with similar models
ModelTP-P400-T3This model TP-P400-T3-ULTP-C400-T3-SAETP-C350-T3-SAETP-P350-T3
Standby400 kW / 500 kVA400 kW / 500 kVA400 kW / 500 kVA359 kW / 448 kVA350 kW / 438 kVA
Prime360 kW / 450 kVA360 kW / 450 kVA360 kW / 450 kVA315 kW / 394 kVA320 kW / 400 kVA
EnginePerkins 2206D-E13TAG3Perkins 2206D-E13TAG3Cummins QSZ13-G7Cummins QSZ13-G6Perkins 2206D-E13TAG2
AlternatorLeroy Somer LSA47.2VS2Leroy Somer LSA46.3L11——Leory Somer LSA46.3L11
Control panelDSE7420Deep Sea DSE 7420——DSE7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480, 120/240120/208, 277/480120/208, 277/480120/208, 277/480120/208, 277/480, 120/240
ConfigurationEnclosed, OpenEnclosed, Open SkidEnclosed, OpenEnclosed, OpenEnclosed, Open
Fuel tank—————
MarketUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certified
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

Supported by Global Generator Supply

+1 251-314-4812

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request