Commercial & Industrial Power Equipment Worldwide

Equipment for use in
400 kW Triton Diesel Generator TP-P400-T3-UL Tier 3 – UL Listed
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 6 technical documentsspec sheet, engine data, alternator data, brochure
60 Hz USA EPA Tier 3 UL2200

400 kW Triton Diesel Generator TP-P400-T3-UL Tier 3 – UL Listed

SKU TP-P400-T3-UL

Standby rating

400 kW 500 kVA

Prime rating

360 kW 450 kVA

Engine
Perkins 2206D-E13TAG3
Alternator
Leroy Somer LSA46.3L11
Control panel
Deep Sea DSE 7420
Fuel
Diesel
Frequency / phase
60 Hz · 3-phase
Voltages listed
120/208 · 277/480
Configuration
Enclosed · Open Skid
Fuel tank
Not specified

Market compatibility

USA EPA-certified

Tier 3 EPA Certified — Emergency Stationary Applications · Tier 3 – UL Listed

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.
Overview

Product overview

The TP-P400-T3-UL is a 500 kVA / 400 kW standby, 450 kVA / 360 kW prime diesel generator, EPA-certified for the US market.

It uses a Perkins 2206D-E13TAG3 engine, a Leroy Somer LSA46.3L11 alternator and a Deep Sea DSE 7420 control panel.

It is listed at 60 Hz, 3-phase, with voltages 120/208 and 277/480, in enclosed or open skid configurations.

  • Engine: Perkins 2206D-E13TAG3
  • Emissions: Tier 3 EPA Certified — Emergency Stationary Applications
  • 60 Hz, three-phase
  • Standby: 400 kW / 500 kVA
  • Prime: 360 kW / 450 kVA
  • Alternator: Leroy Somer
  • Control panel: Deep Sea DSE7420
  • UL 2200 listed

EPA Tier 3 Certified for Emergency Stationary use in the US and Canada.

Triton EPA Generators are compliant for emergency stationary use throughout the United States and Canada.

Why choose this model

  • Perkins 2206D-E13TAG3 engineEngine data sheet included below
  • Standby & prime rated400 kW / 500 kVA standby · 360 kW / 450 kVA prime
  • 60 Hz, 3-phaseVoltages listed: 120/208, 277/480
  • Enclosed or Open SkidConfigurations available for this model
  • Leroy Somer LSA46.3L11 alternatorAlternator specifications included below
  • Deep Sea DSE 7420 control panelControl panel listed for this model

Typical applications

  • government facilities
  • hotels
  • manufacturing plants
  • medical facilities
  • grocery stores
  • data centers

As named in the manufacturer's description of this model.

Listed in our industry catalogs: Data centers, Healthcare, Manufacturing, Oil & gas, Restaurants & hospitality

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-P400-T3-UL
Typical Generator Output Standby: 500 kVA / 400 kW Prime: 450 kVA / 360 kW
Engine
Engine Brand Perkins
Engine Model 2206D-E13TAG3
Engine Power Output 462 kWm / 620 HP @ 1800 RPM
Aspiration Turbocharged Aftercooled
Displacement 12.5 L
Cylinders 6, in line
Speed 1800 RPM
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA46.3L11
Insulation Class H
Electrical
Frequency 60 Hz
Voltages Available 120/208, 277/480
Control
Control Panel Deep Sea DSE 7420
Physical Configuration
Models Available Enclosed, Open Skid
Compliance
Engine Tier Rating Tier 3
Compliance UL 2200 Listed, EPA Tier 3, NFPA 110 compatible
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open Skid

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsTier 3 EPA Certified — Emergency Stationary Applications
MarketUSA EPA-certified
UL 2200Listed
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-P400-T3-UL with similar models
ModelTP-P400-T3-ULThis model TP-P400-T3TP-C400-T3-SAETP-C350-T3-SAETP-P350-T3
Standby400 kW / 500 kVA400 kW / 500 kVA400 kW / 500 kVA359 kW / 448 kVA350 kW / 438 kVA
Prime360 kW / 450 kVA360 kW / 450 kVA360 kW / 450 kVA315 kW / 394 kVA320 kW / 400 kVA
EnginePerkins 2206D-E13TAG3Perkins 2206D-E13TAG3Cummins QSZ13-G7Cummins QSZ13-G6Perkins 2206D-E13TAG2
AlternatorLeroy Somer LSA46.3L11Leroy Somer LSA47.2VS2——Leory Somer LSA46.3L11
Control panelDeep Sea DSE 7420DSE7420——DSE7420
Frequency60 Hz60 Hz60 Hz60 Hz60 Hz
Voltages120/208, 277/480120/208, 277/480, 120/240120/208, 277/480120/208, 277/480120/208, 277/480, 120/240
ConfigurationEnclosed, Open SkidEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, Open
Fuel tank—————
MarketUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certifiedUSA EPA-certified
Project support

Buying this generator for a project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request