Commercial & Industrial Power Equipment Worldwide

Equipment for use in
60 kVA Triton Diesel Generator TP-P60-T1-50  International Use
  • Export supportconfiguration and shipping quotes for your destination
  • Engineering supporthelp with sizing, voltage and configuration
  • 5 technical documentsspec sheet, engine data, alternator data, brochure
50 Hz International

60 kVA Triton Diesel Generator TP-P60-T1-50 International Use

SKU TP-P66-T1-50 Model TP-P60-T1-50

Standby rating

66 kVA 53 kW

Prime rating

60 kVA 48 kW

Engine
Perkins 1103A-33TG2
Alternator
Leroy Somer LSA44.3S2
Control panel
DSE7420
Fuel
Diesel
Frequency / phase
50 Hz · 3-phase
Voltages listed
110/220 · 240/380
Configuration
Enclosed · Open
Fuel tank
320 L

Market compatibility

International market

Triton International generators are not compliant for use in the United States or Canada due to the emissions status.

Specifications being verified

Our engineering team is confirming some details on this page (model). Please confirm model and ratings with sales before ordering.

Need help with voltage, frequency or sizing? Talk to a generator specialist or call +1 251-314-4812.

Destination check

Is this generator right for your destination?

Tell us where it will be used and what it will power. We compare your answers with what is listed for this model, and our engineers confirm the rest before you order.

  • Choose a destination to see what is listed for this model.

Markets with a verified 50 Hz grid: Africa (13) · Middle East (5) · Caribbean & Central America (1) · Latin America (3) · Asia-Pacific (7) · Countries A–Z

Overview

Product overview

The TP-P60-T1-50 is a 66 kVA / 53 kW standby, 60 kVA / 48 kW prime diesel generator for international markets.

It uses a Perkins 1103A-33TG2 engine, a Leroy Somer LSA44.3S2 alternator and a DSE7420 control panel.

It is listed at 50 Hz, 3-phase, with voltages 110/220 and 240/380, in enclosed or open configurations.

  • Engine: Perkins 1103A-33TG2
  • Emissions: Not EPA Certified – Export Use Only
  • 50 Hz, three-phase
  • Standby: 53 kW / 66 kVA
  • Prime: 48 kW / 60 kVA
  • Fuel tank: 320 L

Why choose this model

  • Perkins 1103A-33TG2 engineEngine data sheet included below
  • Standby & prime rated66 kVA / 53 kW standby · 60 kVA / 48 kW prime
  • 50 Hz, 3-phaseVoltages listed: 110/220, 240/380
  • Enclosed or OpenConfigurations available for this model
  • Leroy Somer LSA44.3S2 alternatorAlternator specifications included below
  • DSE7420 control panelControl panel listed for this model

Typical applications

  • hotels
  • marinas
  • factories
  • warehousing
  • government buildings
  • island power

As named in the manufacturer's description of this model.

Technical specifications

Specifications

Values are shown exactly as published. Anything not listed is marked “Not specified”.

Download full specifications
Generator
Triton Model TP-P60-T1-50
kVA / kW Standby 66 kVA / 53 kW
kVA / kW Prime 60 kVA / 48 kW
Engine
Engine Brand Perkins
Engine Model 1103A-33TG2
Alternator
Alternator Brand Leroy Somer
Alternator Model LSA44.3S2
Electrical
Voltages Available 110/220, 240/380
Fuel System
Fuel Tank Capacity 320 L
Control
Control Panel DSE7420
Physical Configuration
Models Available Enclosed, Open
Physical
DimensionsNot specified
WeightNot specified
ConfigurationsEnclosed, Open

Dimensions and weight are not published for this model. Ask for the data sheet.

Compliance & market
EmissionsNot EPA Certified – Export Use Only
MarketInternational market
Configure this generator

Choose your configuration

Options are the ones published for this model. Fuel tank and transfer switch choices are confirmed in your quote.

Frequency
Voltage
Configuration
Duty
Transfer switch needed?
Engineering documents

Technical documents

Specification sheets, engine and alternator data and brochures for this model, for your engineering and procurement teams.

Compatible with this engine

Parts listed for 1103A-33TG2

These parts name this engine model in their own description. Confirm your engine serial number when ordering.

Similar generators

Compare with similar models

Same market and frequency, nearest in size. Tick up to three to compare with this model.

Comparison of TP-P60-T1-50 with similar models
ModelTP-P60-T1-50This model TP-P67-T1-S-K-50TP-P45-T1-50TP-P80-T1-50TP-P30-T1-50
Standby66 kVA / 53 kW71 kVA / 57 kW49 kVA / 39 kW88 kVA / 70 kW33 kVA / 26 kW
Prime60 kVA / 48 kW65 kVA / 52 kW45 kVA / 36 kW80 kVA / 64 kW30 kVA / 24 kW
EnginePerkins 1103A-33TG2Perkins 1104A-44TG1Perkins 1103A-33TG1Perkins 1104A-44TG2Perkins 1103A-33G
AlternatorLeroy Somer LSA44.3S2Leroy Somer TAL044 CLeroy Somer LSA42.3M7Leroy Somer LSA44.3S4Leroy Somer LSA42.3VS3
Control panelDSE7420DSE7310DSE7420DSE7420DSE7420
Frequency50 Hz50 Hz50 Hz50 Hz50 Hz
Voltages110/220, 240/380220/380110/220, 240/380110/220, 240/380110/220, 240/380
ConfigurationEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, OpenEnclosed, Open
Fuel tank320 L160 L320 L200 L160 L
MarketInternational marketInternational marketInternational marketInternational marketInternational market
International export support

Buying this generator for an international project?

Our team can help configure it for your destination, and quote documentation and shipping on request, or you can use your own forwarder.

  • Engineeringhelp with sizing, voltage and configuration
  • Export supportdocuments and shipping quotes on request
  • Partsparts and components for your equipment
  • Quote listcombine several products in one request