60 HzUSA EPA
200 kW Triton Diesel Generator TP-C200-T3 EPA Certified
TP-C200-T3
Engine Cummins QSB7-G5
- Standby
- 200 kW / 250 kVA
- Prime
- 180 kW / 225 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
The 12 Cummins EPA generators listed here are 60 Hz diesel sets for the US market, each labeled USA EPA-certified, in other words an "EPA-certified configuration for the US market." Standby ratings range from 200 kW to 2,250 kW.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzUSA EPA
TP-C200-T3
Engine Cummins QSB7-G5
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C250-T3
Engine Cummins QSL9-G3
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C300-T3-SAE
Engine Cummins QSL9-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C350-T3-SAE
Engine Cummins QSZ13-G6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C400-T3-SAE
Engine Cummins QSZ13-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C450-T3
Engine Cummins QSX15-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPAMobile
TP-C500-T3
Engine Cummins QSX15-G9
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C800-T2-60
Engine Cummins QSK23-G7
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C1000-T2-60
Engine Cummins QST30-G5
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C1500-T2-60
Engine Cummins QSK50-G4
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C2000-T2-60
Engine Cummins QSK60-G6
Diesel · 60 Hz · Enclosed or open
60 HzUSA EPA
TP-C2250-T2-60
Engine Cummins QSK60-G14
Diesel · 60 Hz · Enclosed or open
Showing 12 of 12
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 12 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 12 units here, 12 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 12 of the 12 units here are offered in more than one configuration. 4 are mobile units.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
The 12 Cummins EPA generators listed here are 60 Hz diesel sets for the US market, each labeled USA EPA-certified, in other words an "EPA-certified configuration for the US market." Standby ratings range from 200 kW to 2,250 kW.
A standby rating describes what a set can supply as backup power while the utility is out. If the generator is expected to carry the site as its main source over long periods with a varying load, the prime rating applies, and it is lower than the standby figure for the same set. Comparing the correct rating against your load helps avoid an undersized unit.
Of the 12, 4 are mobile units, and all list enclosed and open configurations. Our team can help confirm the right unit after you send your requirements through the quote form.
Tell us your required power, destination and application. Our team can help identify the right generator.