Commercial & Industrial Power Equipment Worldwide

Equipment for use in
Diesel Generators

How EPA Emission Tiers Apply to Diesel Generators

· 3 min read

EPA Tier Ratings for Generators

Federal control of air pollution in the United States goes back to the mid-1950s. Later, when the Environmental Protection Agency (EPA) set rules for the exhaust from diesel engines, manufacturers had to make their engines perform better while releasing fewer pollutants into the air.

Generator sets were not what those rules first set out to regulate, but they fall under them now. Stationary diesel engines and non-road mobile diesel engines, the kinds that drive generator sets, are both subject to close EPA oversight.

How the Tier System Works

Rather than impose every reduction at once, the EPA brought them in stages. That gave scientists, engine makers and the wider market time to develop the technology, the know-how and the funding that compliance demanded. Each tier sets a ceiling on emissions, and every new tier is built on the one that came before it.

Tier 1

The starting point was 1990, when the federal government took on considerably more authority and responsibility, including the power to authorize operating permits for stationary sources. Tier 1 introduced the first emission limits for new non-road mobile diesel engines; engines built for locomotives and marine vessels were left out.

Tier 2

The second tier made the pollution limits tighter. It dealt with four kinds of emissions: particulate matter (PM), carbon monoxide, unburned hydrocarbons and NOx, which is shorthand for the mono-nitrogen oxides NO2 and NO. Its requirements reached engines of every size, phasing in from 2001.

Tier 3

Between 2006 and 2008, Tier 3 rules took effect and capped exhaust emissions from engines rated between 50 and 750 hp.

Tier 4

The EPA signed the Tier 4 final rule on May 11, 2004, with a phase-in planned between 2008 and 2015. Sulfur content had not been tightly regulated under the first three tiers, and the EPA made reducing it part of Tier 4.

The Tier 4 standards call for PM and NOx emissions to be cut by 90 percent. Those cuts come from new control technologies much like the ones required of highway engines from 2007 to 2010, which included advanced after-treatment of the exhaust gas.

What Tier 4 Means in Practice

Generators certified to Tier 4 carry no limits on run time, so they can supply backup power whenever it is called for. That gives their owners considerable freedom in how they use the equipment.

These generators are aimed at buyers who care about the environment. They rely on advanced emissions-control technology, with the goal of bringing exhaust emissions down close to zero. The stricter standards are expected to prevent 12,000 premature deaths each year by 2030.

Where Diesel Engine Rules Stand Now

Under the New Source Performance Standards, most stationary diesel engines must meet Tier 2, 3 or 4 emission limits, with the applicable tier set by the engine's power range. From 2011 onward, Tier 4 rules cover non-emergency diesel engines above 175 horsepower that displace less than 10 liters per cylinder.

A generator classed as an emergency unit may run only when the main source of electrical power has failed. Outside of emergencies it may run for testing and maintenance, up to a limit of 100 hours a year. These limits grew out of the EPA's drive to cut air toxics, pollutants and other harmful diesel-fuel emissions, an effort that has brought major health and environmental gains along with new advanced technology.

Tier 4 Diesel Generators for Critical Sites

Hospitals, emergency dispatch centers, schools and airports are not spared when the grid goes down. When power fails at places like these, the harm can be severe and lives can be put at risk. Standby generators let them keep running even after the utility lines go dead.

If you need an EPA-certified Tier 4 diesel generator for a facility like these, send us your requirements and our team can help you choose a suitable unit. You can also browse the Tier 4 generators on our site.