Commercial & Industrial Power Equipment Worldwide

Equipment for use in

Yanmar EPA Generators

Yanmar EPA Generators are a short list: 2 Triton diesel sets for US installations, with standby ratings from 30 kW to 38 kW.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Configuration

2 of 2 generators

Generators

Buyer's guide

Choosing the right generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 2 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 2 units here, 2 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 1 of the 2 units here are offered in more than one configuration.

USA EPA, Tier 4 Final or international?
  • USA EPA (2 here): EPA-certified configuration for the US market.

About Yanmar EPA Generators

Yanmar EPA Generators are a short list: 2 Triton diesel sets for US installations, with standby ratings from 30 kW to 38 kW.

  • Market: EPA-certified configuration for the US market.
  • Engine: Yanmar diesel on both.
  • Housing: enclosed on both, with an open version also listed for 1.
  • Frequency: 60 Hz, matching North American grids.

With just 2 units, the choice mostly comes down to which end of that range fits the load. Both figures are standby ratings, the output meant for backup when utility power fails. Ratings are normally given at a 0.8 power factor, so dividing kW by 0.8 gives the kVA value if your equipment is listed that way.

For a site outside the US, see Yanmar export generators. Send your requirements through the quote form.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.

Compare generators

Values as published for each unit. Full specifications, documents and any market restriction are on each product page.