60 HzTier 4 FinalMobile
110 kW Triton Diesel Generator TP-JD110-T4F Tier 4 Final
TP-JD110-T4F
Engine John Deere 4045HFG09
- Standby
- 110 kW / 138 kVA
- Prime
- 100 kW / 125 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
How the generator will be used matters more here than layout or engine. The 101-300 kW Tier 4 Final Generators are 9 Triton diesel units, all of them mobile, with standby ratings of 110 kW up to 300 kW at 60 Hz.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzTier 4 FinalMobile
TP-JD110-T4F
Engine John Deere 4045HFG09
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD125-T4F-RENTAL
Engine John Deere 4045HFG09
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD165-T4F
Engine John Deere 6068HG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD190-T4F-Rental
Engine John Deere 6068HG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD200-T4F
Engine John Deere 6068CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD225-T4F-RENTAL
Engine John Deere 6068CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-JD288-T4F
Engine John Deere 6090CG550
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-S300-T4F
Engine Scania DC13 084A
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RJD325-T4F-RENTAL
Engine John Deere 6090CG550
Diesel · 60 Hz · Enclosed or open
Showing 9 of 9
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 9 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 9 units here, 9 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 9 of the 9 units here are offered in more than one configuration. 9 are mobile units.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
How the generator will be used matters more here than layout or engine. The 101-300 kW Tier 4 Final Generators are 9 Triton diesel units, all of them mobile, with standby ratings of 110 kW up to 300 kW at 60 Hz.
John Deere engines are fitted to 8 of the 9 and a Scania engine to 1, and each unit is listed both enclosed and as an open set. The market label on every listing reads: Tier 4 Final emissions configuration.
Use decides which rating to read. A standby rating covers emergency backup, when the set runs only while the utility supply is down. A prime rating covers a generator serving as the main power source for extended periods, with the load rising and falling, and it sits below the standby rating of the same unit. If you expect long running hours, size against prime. Smaller units are on the smaller Tier 4 Final generators page. Send your requirements through the quote form and note the expected running pattern.
Tell us your required power, destination and application. Our team can help identify the right generator.