60 HzTier 4 FinalMobile
1100 kW Triton Diesel Generator TP-V1100-T4F-Twin Pack
TP-V1100-T4F-Twin Pack
Engine Volvo TWD1672GE
- Standby
- 1,100 kW / 1,376 kVA
- Prime
- 1,000 kW / 1,250 kVA
Diesel · 60 Hz · Enclosed or open
Commercial & Industrial Power Equipment Worldwide
Every unit listed under 1001 kW and up Tier 4 Final Generators carries one label: Tier 4 Final emissions configuration. There are 4 of them, all Triton diesel sets on Volvo engines, rated from 1100 kW to 1254 kW standby at 60 Hz.
Filter by power, engine, frequency, market eligibility and configuration to find the right unit.
60 HzTier 4 FinalMobile
TP-V1100-T4F-Twin Pack
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV1250-T4F-RENTAL TWIN PACK
Engine Volvo TWD1672GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-RV1425-T4F-RENTAL TWIN PACK
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
60 HzTier 4 FinalMobile
TP-V1250-T4F-Twin Pack
Engine Volvo TWD1673GE
Diesel · 60 Hz · Enclosed or open
Showing 4 of 4
No products match these filters.
Many units can be configured to the specification you need. Ask about a custom configuration or .
Five questions that decide which unit fits. Each unit's page has its full published specifications.
A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.
All 4 units here publish both ratings; on each of them the standby rating is the higher figure.
Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.
Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.
Of the 4 units here, 4 at 60 Hz.
Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 4 of the 4 units here are offered in more than one configuration. 4 are mobile units.
EPA generatorsTier 4 Final generatorsExport generatorsDo you need a Tier 4 generator?
Every unit listed under 1001 kW and up Tier 4 Final Generators carries one label: Tier 4 Final emissions configuration. There are 4 of them, all Triton diesel sets on Volvo engines, rated from 1100 kW to 1254 kW standby at 60 Hz. All 4 are mobile units, and each is listed in both an enclosed and an open layout.
At this output, loads and switchgear are often specified in kVA as well as kW. The relationship is simple: kVA is the kW figure divided by the power factor, and generator ratings are usually quoted at a power factor of 0.8. Use the kVA to kW calculator when a load list arrives in kVA, then compare the result with the standby figures on this page.
Keep in mind that standby is the rating for backup during outages; a set running as the main supply is held to its lower prime rating. Other sizes with the same emissions label are on the Tier 4 generators page. With your load list ready, send your requirements through the quote form.
Tell us your required power, destination and application. Our team can help identify the right generator.