0-100 kW Tier 4 Final Generators

At 13.5 kW to 88 kW standby, the 10 Triton units in the 0-100 kW Tier 4 Final Generators group cover the small end of the load scale, and every one is a 60 Hz mobile diesel set.

Filter by power, engine, frequency, market eligibility and configuration to find the right unit.

Power
Engine

10 of 10 generators

Generators

Buyer's guide

Choosing a 0–100 kW generator

Five questions that decide which unit fits. Each unit's page has its full published specifications.

Standby or prime?

A standby rating is for backup duty: the generator starts when utility power fails and carries the load until the grid comes back. A prime rating is for sites where the generator is the main source of power, running for long periods while the load rises and falls.

All 10 units here publish both ratings; on each of them the standby rating is the higher figure.

kW or kVA?

Generators are rated in kVA and kW. kVA = kW ÷ power factor, and generator ratings typically use a power factor of 0.8. A few units are published with other ratios, so always use the unit's own kW and kVA figures. International ratings are often quoted in kVA: switch this list between kW and kVA in the toolbar.

50 Hz or 60 Hz?

Generator frequency has to match the local grid and the equipment on it. Grids in North America run mainly at 60 Hz, while Europe and much of Asia and Africa run at 50 Hz. Set the project destination above to see its grid frequency.

Of the 10 units here, 10 at 60 Hz.

Open or enclosed?

Each unit's page lists the configurations it is offered in (enclosed, open), with dimensions and weights where published. 10 of the 10 units here are offered in more than one configuration. 10 are mobile units.

USA EPA, Tier 4 Final or international?
  • Tier 4 Final (10 here): Tier 4 Final emissions configuration.

About 0-100 kW Tier 4 Final Generators

At 13.5 kW to 88 kW standby, the 10 Triton units in the 0-100 kW Tier 4 Final Generators group cover the small end of the load scale, and every one is a 60 Hz mobile diesel set.

Engines, label and layouts

  • Kubota engines power 6 units.
  • John Deere engines power 4 units.
  • Market label: Tier 4 Final emissions configuration.
  • All 10 are listed with an enclosure and also as open sets.

Choosing between those layouts depends on where the generator will sit. An open set fits inside an engine room or a similar sheltered space; an enclosure protects the machine from rain and dust and keeps engine noise down when it stands outdoors.

Ratings here are quoted in kW, but if your equipment list is in kVA, remember that kVA equals kW divided by the power factor, normally taken as 0.8 for generators. Larger units with the same emissions label are grouped under Tier 4 generators. Once the load and the site layout are known, send your requirements through the quote form.

Can't find the right configuration?

Tell us your required power, destination and application. Our team can help identify the right generator.